43/50
User Manual for HYD 3-6 kw ES Hybrid Inverter - Rev. 1.1 del 13/06/2019
Identificazione: MD-AL-GI-00
Rev. 4.0 del 31.01.18 - Applicazione: GID
AC Parameters
Maximum output power
3000W
4000W
5000W
6000W
Maximum output current
13.7A
18.2A
22.8A
27.3A
Rated grid and frequency
voltage
230V, 47 – 53Hz or 57 – 63Hz
AC voltage range
150 – 275V (according to the local requirements)
Total harmonic current distortion
<3%
Power factor
1 (adju/-0.8)
Inrush current
0.8A/1us
Maximum output fault current
100A/1us
System Parameters
Maximum efficiency
Charge: 94.6%/ discharge 94.6%
Standby losses
< 5W (Photovoltaic SPS)
Topology
High-frequency isolation transformer
Degree of protection
IP 65
Safety protection
Anti-islanding, RCMU (Residual Current Monitoring Unit), ground fault
monitoring
Communication
Wi-Fi, RS485, CAN2.0B
Environmental Data
Ambient temperature range
-25C to +60C (derating above +45C)
Relative humidity range
0% – 100% (non-condensing)
Protection class
Class I
Maximum operating height
2000m
Current transformer connection
Hard wired
General information
Noise
<25dB
Weight
20.5kg
Cooling
Natural convection
Dimensions (W*H*D)
532 x 360 x 173 mm
Display
Crystal Liquid Display
Warranty
10 years
EPS (Emergency Power Supply) Data
Maximum EPS power
3000VA
EPS rated voltage/frequency
230V, 50/60Hz
EPS estimated current
13A
Total harmonic current distortion
<3%
Switch-over time
Default <20mS