37/50
User Manual for HYD 3-6 kw ES Hybrid Inverter - Rev. 1.1 del 13/06/2019
Identificazione: MD-AL-GI-00
Rev. 4.0 del 31.01.18 - Applicazione: GID
2.
Reset Energy Data
Select “2. Reset Energy”, then press “OK” to reset the energy data.
3.
Clear events
Select “3. Clear Events,” then press “OK” to clear all the events.
4.
Country (refer to
Set country)
Select “4. Country”, press “OK”, the settings of the current country appear. Press “Up” or “Down” to change the
first digit, press “OK” to move to the next one. Enter the new country code and press “OK.”
5.
Anti Reflux
5.Anti Reflux control
1.Anti Reflux control
Enabled
Disabled
2. Reflux Power
***KW
The user can enable the “Anti Reflux Control” to limit the maximum energy exported to the grid.
Select “2. Reflux Power” to enter the maximum amount of energy exported to the grid.
6.
IV Curve Scan
6.IV Curve Scan
1.Scan Control
Enabled
Disabled
2.Scan Period
***min
3.Force Scan
The user can enable the “IV Curve Scan” (scan MPPT) to have the HYD-ES periodically check the absolute
maximum power points to provide maximum energy from a partially shaded PV array.
The user can enter the scan period or force an immediate scan.
7.
Safety parameters (and other functions not previously described that appear in the user interface)
Contact ZCS Technical Support for more information.