13/50
User Manual for HYD 3-6 kw ES Hybrid Inverter - Rev. 1.1 del 13/06/2019
Identificazione: MD-AL-GI-00
Rev. 4.0 del 31.01.18 - Applicazione: GID
12
Dust mask
Must be worn by operators
3.5.
Wall installation position
The HYD-ES inverter must be mounted vertically (to ensure rapid heat dissipation). Install the HYD-ES inverter
in a location protected against direct sunlight and possible snow accumulation. Make sure that the installation
position is well ventilated.
Figure 4 – Installation position of the HYD-ES inverter
3.6.
Mounting instructions
Step 1:
Position the mounting bracket on the wall, mark the 8 fixing points using the marker. Drill 8 holes (6
mm drill bit) in the wall.
Step 2:
Insert the expansion screws vertically into the hole, make sure that the insertion depth is neither too
shallow nor too deep.
Step 3:
Fix the mounting bracket to the wall using dowels and flat washers.