23. QUICK INFO ON SYSTEM STATUS
Press from the main menu to access the instant information on
the battery and AC grid.
Press from the main menu to access the instant information on the
DC-side of the inverter.
24. OPERATING STATUSES IN AUTOMATIC MODE
When the power produced by the photovoltaic system
is greater than the energy required by the loads, the
inverter will charge the battery with the excess
energy.
When the battery is fully charged, or when the
charging power is limited (to preserve the integrity of
the battery), the excess energy will be exported to
the grid.
Charge
When the power of the photovoltaic system is once
again less than the power required by the loads, the
system will use the energy stored in the battery to
power the household loads.
Discharge
When the total power produced by the photovoltaic
system and supplied by the battery is less than that
required by the loads, the missing energy will be
taken from the grid.
Charge
Charge
Discharge
Discharge
33