After activating the photovoltaic system, check that:
The consumption value remains constant as the
photovoltaic power output increases.
Note
: If the conditions described above are not met:
•
Check that the current sensor is correctly positioned and then proceed with
restarting the system.
* Check that the power of the loads in use does not change:
•
Heat pumps or pumps → Load may vary over time
•
Lights or hairdryers → Load remains constant over time
4) Switch on the photovoltaic system by flipping the
DC circuit breaker to the ON position
5) Switch on the battery or batteries, ensuring that
the system operates in the mode described in the
section
OPERATING STATUSES IN AUTOMATIC
MODE:
•
PV>Load →battery charging
•
PV<Load Battery discharging
•
PV=Load Battery on stand-by
NOTE: At the initial start-up, the batteries will charge up to 100%
ON
GRID
OFF
ON
1
2
3
ON
GRID
ON
1
2
Battery
ON
3
25