58 / 136
Identification: MD-AL-GI-00
Rev. 1.1 of 15/03/2021 - Application: GID
User’s Manual 3PH 20000TL - 33000TL-V2
Rev. 1.1 15/03/2021
Modbus address
Select “9. ModBusAddress” and press “OK” to enter the menu for selecting the communication address. Use
the “Up” and “Down” keys to select the number and “OK” to move to the next one, and confirm. After setting
the address, press “OK.”
The Modbus address indicates the address used by the inverter to send its data to the monitoring server.
Address 01 is used for single inverters; to extend the monitoring to multiple inverters, use progressive
communication addresses.
Note: make sure that the address entered is never 00, because this setting would exclude the possibility of
communication between the inverter and the Wi-Fi network or RS485 port.
Set MPPT
Selection of the input mode: 3PH 20000TL - 33000TL-V2 inverters are equipped with two MPPTs, which can
operate independently or in parallel, depending on the requirements of the system in which they are
installed. The input mode can be set by the user via the LCD display.
Select “10. MPPT” and press “OK” to enter the menu for setting the input mode. Press the “Up” and “Down”
keys to change the input mode between “1. Parallel” and “2. Independent,” then press “OK” to confirm. If the
setting is successful, “OK” will be displayed; otherwise, “Error” will be displayed.
Language
Select “11. Language” and press “OK” to enter the menu for selecting the language. Select the language using
the “Up” and “Down” keys; then press “OK” to confirm. If the operation is successful, “OK” will be displayed;
otherwise, “Error” will be displayed.
A faster way to change the language is to press the “Menu/Back” key and the “OK” key at the same time. In
the current firmware version (V1.60), the languages available are: Chinese, English, Italian, German, French,
Ukraine, Slovakia and Portuguese; future firmware updates may add new languages.
Initial parameters
The user can change the start parameters directly from the LCD display. The user must first copy the TXT
files to the SD card. These files can be requested from ZCS technical support.
Select “12. InitParameters” and press “OK” to enter the menu for setting the start parameters. The display
will show “Enter PWD!”, press “OK” to enter the password. Enter the password “0001” using the “Up” and
“Down” keys to select the digit and “OK” to move to the next one, and confirm. If the display shows
“Incorrect, try again!” press the “Back” key and enter the password again. When the password entered is
correct, you can enter the menu. The new start parameters will now be loaded onto the inverter
automatically.
If the setting is successful, “OK” will be displayed; otherwise, “Error” will be displayed.
Attention: do not enter this menu if the microSD card is not inserted in the appropriate slot of the inverter
or if the correct TXT files have not been copied to it.
Safety Voltage
The user can change the value of the protection voltage directly from the LCD display. The user must first
copy the TXT files to the SD card. These files can be requested from ZCS technical support.
Select “13. Safety V” and press “OK” to enter the menu for setting the protection voltage. The display will