AUTOMATIC GATE OPENER
• Installation Manual
26
Setting the Transmitter Code
NOTE:
All Zareba Automatic Gate Opener transmitters
and receivers use a standard code set at the factory. It
is recommended that you set your own personal code
for safety and security.
Step 1
(fig. 39)
Remove the battery access cover on the transmitter.
When the cover is off, you will see the battery and the
DIP switch.
Step 2
The DIP switch contains 10 small switches (
fig. 40
).
Using a small screwdriver or pen, move any single or
combination of the switches to either the open or
closed position.
NOTE:
Do not set the switches to all open or all closed.
Step 3
Remove the RF receiver box cover by removing the four
screws. When the cover is off, you will see the DIP
switches in the upper right corner.
Step 4
There are 10 small DIP switches. Refer to the transmitter
and using a small screw driver or pen, move the switch-
es to the same positions as you did for the transmitter
(
fig. 40
).
NOTE:
The transmitter and RF receiver DIP switch set-
ting must match exactly or the remote system will not
work.
Figure 40
Figure 39
DIP switch
To Set or Clear Position Limits:
4 ON
To set or clear second gate
position limit
4 OFF
To set or clear first gate
position limit
1 OFF; 2 ON; 3 ON
First and second gates open
at the same time. Second
gate begins to close eight
seconds before first gate.
1 OFF; 2 ON; 3 OFF
First and second gates open
at the same time. Second
gate begins to close four
seconds before first gate.
1 ON; 2 OFF; 3 ON
First gate begins to open
two seconds before second
gate. Second gate begins to
close eight seconds before
first gate.