Solutions for Malfunctions
7. Malfunctions of lamps, instruments, switches and indicating lamps (cont’d)
4) MALFUNCTIONS OF BACKUP LIGHT
Trouble designation
Trouble description
Remedy
Backup light is off.
Lamps are damaged
Check lamps
Fuse (F11) of backup light blows out
Check fuse, replace if necessary
(In case of replacement, check for short circuit)
Malfunctions of backup light switch
Check switch
Malfunctions of wires or ground
Repair the circuit
Turning off backup light
can not be turned off.
Malfunctions of backup light switch
Check or replace switch
5) MALFUNCTIONS OF STOP LAMP
Trouble designation
Trouble description
Remedy
Stop lamp is off.
Lamp is damaged
Check lamp
Fuse (F2) of stop lamp blows out
Check fuse, replace if necessary
(In case of replacement, check for short circuit)
Malfunctions of switch for service brake lamp
Check switch for service brake lamp
Malfunctions of wires or ground
Repair the circuit
Malfunctions of switch for stop lamp
Check, adjust or change switch