5. OPERATION
SYNTHESIS E
23
The oven continues working and only probe 1 is used to measure the
temperature. The control temperature is automatically raised by 40°C.
This variation in the temperature value is effected to correct the only
value taken in the coldest part of the oven and to simulate a value near to
the real one previously elaborated by making the average between the
hottest and coldest points. This allows the oven to be used even when a
probe breaks.
5.6.3.
“OVER”
If the temperature measured by the probe 1 exceeds 350°C and, at the
same time, probe 2 exceeds 450°C, the temperature value on the display is
replaced by the flashing word “OVER” and the alarm sounds intermittently.
You can switch off the alarm by pressing the key
.
Necessary to call in specialists to restore functionality
5.6.4.
“BELT”
When the conveyor motor is broken or sends wrong signals to the circuit
board, the word “BELT” flashes on the display and the alarm sounds
intermittently.
This means that the cooking time does not correspond to the set value
and that specialized personnel are required to reset the functions of the
oven.
5.6.5.
“BATTERY”
When the buffer battery installed on the main electronic board is
exhausted, an alarm is activated on the display together with the flashing
writing "BATTERY" and the acoustic signal plays in intermittent way. To
replace the battery see paragraph 8.3.
Summary of Contents for SYNTHESIS 12/80V E
Page 34: ......
Page 40: ...SYNTHESIS 12 80 VE C 1 N L1 L2 L3 IMPI0192 ...
Page 41: ...SYNTHESIS 12 80 VE C 2 ...
Page 42: ...SYNTHESIS 12 80 VE C 3 L1 L2 L3 IMPI0192 3 ...
Page 46: ...SYNTHESIS 12 80 VE ...
Page 47: ...SYNTHESIS 12 80 VE ...
Page 50: ...SYNTHESIS 12 80 VE ...
Page 51: ...SYNTHESIS 12 80 VE ...
Page 52: ......
Page 56: ...SYNTHESIS BM A B ...