12
5.4 Configuring the Z3-MVE-100
(5) Power on the Z3-MVE-100.
(6) Wait around 30 seconds to 1 minute.
(7) Open a web browser (FireFox is recommended). Type in
http://192.168.81.68
. You should
then see the Z3-MVE-100 Configuration Menu (if you don’t see this, please see the
Troubleshooting section on page 30).
Figure 7 Windows PC IP Address – Internet Protocol Window
Set to 192.168.0.6 (or whatever
value you decide on that begins with
192.168.x.y and does not equal
192.168.81.68)
Make sure the netmask is
set to “255.255.0.0”
Figure 8 Z3-MVE-100 Demo Connections (Front)
(1) Turn on PWR
(2) LED lights up