4.7 CHECKING POWDER LEVELS
If you do not have enough powder to complete
your build, you will need to fill the powder
feeder. To view how much powder is left in the
feeder, choose ‘Get Piston Levels’ under the
Service menu or using the control panel raise
or lower the build piston the LCD will read “F:
X%. B: Y%.” (Where X corresponds with the
powder level in the feeder and Y corresponds
with the build level available.)
The powder levels are given in four-inch
increments ONLY.
To fill the feeder:
1. Turn on vacuum.
2. Place vacuum hose into powder feeder
vacuum receptacle.
3. Vacuum powder from powder container.
4. The powder feeder vacuum will shut down
when it is full.
Technical Tip –
Use a nozzle or vacuum at an angle when
filling the powder feeder. This will promote
airflow through the vacuum hose.
PLEASE NOTE:
Never add powder from
container until all powder has been
vacuumed out of the build area and
overflow chute has been emptied.
PLEASE NOTE:
If the feeder detects that
it is full, it will shut off the vacuum and stir
the powder in the feeder for 30 seconds. If
it no longer detects that it is full after
stirring, the feeder will turn the vacuum
back on. This continues until the detector
reads full after stirring. When the feeder
detects that it is full, the vacuum switch will
not turn on the vacuum until powder is
dispensed from the feeder.