18
DynaPak 3010RNM Version 01102001 ATEX Rev.
YZ Systems, Inc. • 3101 Pollok Drive • Conroe, Texas • USA • 77303 • P: 936.788.5593 • F: 936.788.5720
9.3 Battery Test:
1. Set the mode switches as follows:
a. Position 1, 2 and 3 on
b. Position 4 off.
c. Set the time switches to the 01
position.
NOTE: time switches must not be in 00
position to test the battery.
This will set the solenoid output rate to one
actuation every one minute (based on the
factory set time range for the Z-65/6.1 model).
2.. Depress the test switch to test the battery.
A green LED will illuminate if the battery is
good and a red LED will illuminate if the battery
is low.
NOTE: the solenoid must be connected to
test the battery condition. Battery condition
cannot be tested with a volt meter.
Replacing a Depleted Battery:
1. Remove the four thumb screws, cover plate
and orange terminal connector.
2. The battery is located in the lower left hand
corner of the Z-65/6.1 controller assembly.
3. Unclip the battery plug from the battery
receptacle.
4. Replace the depleted battery with a fresh
battery pack (part No. E3-2001).
NOTE: follow the illustration to assure proper
battery wire placement in the Z-65/6.1 enclo-
sure.
5. Return the mode switches to their original
positions.
6. Send your depleted battery to:
YZ Systems Inc.
206 Lubbock Hwy.
Snyder, TX 79549 USA
Battery Pack
9. Sampler maintenance: