Unitary Products Group
CP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by
the total electric power input during the same period.
— = Not Applicable.
COP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by
the total electric power input during the same period.
1 PH 13 SEER HP WITH AHP/ SHP
YMB01811
AHP18
–
17.5
3.40
1.51
10.6
2.40
1.29
8.00
F*FP024
–
17.5
3.40
1.51
10.6
2.40
1.29
8.00
YMB02411
AHP24
–
23.6
3.20
2.16
14.6
2.20
1.94
8.00
YMB03011
AHP30
–
29.6
3.40
2.55
18.0
2.20
2.40
8.00
F*FP040
–
29.6
3.40
2.55
18.0
2.20
2.40
8.00
YMB03611
AHP36
–
36.0
4.00
2.78
22.6
2.58
2.58
9.25
AHP42
–
36.0
4.00
2.78
22.6
2.58
2.58
9.25
YMB04211
AHP/SHP48
–
42.0
3.78
3.25
28.8
2.56
3.30
8.60
AHP/SHP60
–
42.0
3.90
3.15
28.2
2.64
3.13
8.80
F*FP045
–
42.0
3.78
3.25
28.8
2.56
3.30
8.60
YMB04811
AHP/SHP48
–
48.0
3.72
3.78
33.4
2.58
3.79
8.50
AHP/SHP60
–
48.0
3.82
3.68
33.0
2.66
3.63
8.70
YMB06011
AHP/SHP60
–
58.0
3.60
4.72
39.0
2.40
4.76
8.05
1
Rated CFM same as for cooling.
2
Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and
no supplemental electric heat operation.
HEATING PERFORMANCE - Air Handlers
UNIT
MODEL*
AIR
HANDLER
COIL
1
MODEL
ARI HEATING
2
47
°
F
17
°
F
HSPF
MBH
COP
KW
MBH
COP
KW
STD
HEATING PERFORMANCE - Furnace Coils
UNIT
MODEL*
COIL
1
MODEL
ARI HEATING
2
47
°
F
17
°
F
HSPF
MBH
COP
KW
MBH
COP
KW
STD
YMB01811
FC/MC/PC/UC18
17.5
3.40
1.51
10.6
2.40
1.29
8.00
HC18
17.5
3.40
1.51
10.6
2.40
1.29
8.00
YMB02411
FC/MC/PC/UC24
23.6
3.20
2.16
14.6
2.20
1.94
8.00
FC/MC/PC/UC30
23.6
3.20
2.16
14.6
2.20
1.94
8.00
HC30
23.6
3.20
2.16
14.6
2.20
1.94
8.00
HD24
23.6
3.20
2.16
14.6
2.20
1.94
8.00
YMB03011
FC/MC/PC35
29.6
3.40
2.55
18.0
2.20
2.40
8.00
FC/MC/PC/UC42
29.6
3.40
2.55
18.0
2.20
2.40
8.00
HC36
29.6
3.40
2.55
18.0
2.20
2.40
8.00
HD36
29.6
3.40
2.55
18.0
2.20
2.40
8.00
YMB03611
FC/MC/PC/UC42
35.0
4.00
2.78
22.6
2.58
2.57
8.50
FC/MC/PC/UC48
36.0
4.00
2.78
22.6
2.58
2.57
8.50
HC42
36.0
4.00
2.78
22.6
2.58
2.57
8.50
HD48
36.0
4.00
2.78
22.6
2.58
2.57
8.50
YMB04211
FC/MC/PC/UC60
42.0
3.76
3.27
29.0
2.54
3.34
8.50
HC60
42.0
3.76
3.27
29.0
2.54
3.34
8.50
HD60
42.0
3.76
3.27
29.0
2.54
3.34
8.50
YMB04811
FC/MC/PC/UC60
48.0
3.76
3.74
33.4
2.58
3.79
8.60
HC60
48.0
3.76
3.74
33.4
2.58
3.79
8.60
HD60
48.0
3.76
3.74
33.4
2.58
3.79
8.60
YMB06011
FC/MC/PC/UC60
58.0
3.58
4.75
40.0
2.40
4.88
8.00
MC61
58.0
3.58
4.75
40.0
2.40
4.88
8.00
HC60
58.0
3.58
4.75
40.0
2.40
4.88
8.00
HD60
58.0
3.58
4.75
40.0
2.40
4.88
8.00
1
Rated CFM same as for cooling.
2
Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping
and no supplemental electric heat operation.