![York YMB018 THRU 060 Technical Manual Download Page 17](http://html1.mh-extra.com/html/york/ymb018-thru-060/ymb018-thru-060_technical-manual_4253441017.webp)
246809-YTG-E-0507
Unitary Products Group
17
Multipliers for determining the performance with other indoor sections
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
COOLING PERFORMANCE DATA
OUTDOOR UNIT MODEL NO.
YMB03611
INDOOR COIL MODEL NO.
FC/MC/PC/UC48
CONDENSER
ENTERING AIR
TEMPERATURE
ID CFM
1000
1200
1400
ID DB (°F)
80
80
75
80
80
80
80
75
80
80
80
80
75
80
80
ID WB (°F)
57
62
62
67
72
57
62
62
67
72
57
62
62
67
72
65
T.C.
33.3
36.9
35.5
35.8
39.2
35.5
37.4
37.8
34.5
40.7
37.6
37.9
40.1
33.2
42.3
S.C.
32.7
33.6
25.5
22.7
18.5
34.9
34.7
29.6
20.8
20.1
37.0
35.7
33.8
19.0
21.8
K.W.
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
75
T.C.
32.5
35.5
33.9
34.2
37.7
34.4
36.1
35.0
33.8
39.2
36.4
36.6
36.1
33.3
40.6
S.C.
31.9
32.9
24.9
22.1
17.8
33.9
34.0
27.2
21.6
19.5
35.9
35.0
29.4
21.1
21.1
K.W.
2.0
2.0
2.0
2.0
2.1
2.0
2.0
2.0
2.0
2.1
2.0
2.0
2.0
2.0
2.1
85
T.C.
31.6
34.2
32.3
32.7
36.3
33.4
34.8
32.1
33.0
37.6
35.2
35.4
32.0
33.3
38.8
S.C.
31.1
32.2
24.4
21.4
17.1
33.0
33.3
24.7
22.4
18.8
34.8
34.4
25.0
23.3
20.5
K.W.
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
95
T.C.
30.8
32.8
30.7
31.2
34.9
32.4
33.4
29.3
32.3
36.0
34.0
34.1
27.9
33.3
37.1
S.C.
30.3
31.5
23.9
20.8
16.3
32.0
32.6
22.2
23.1
18.1
33.7
33.7
20.6
25.5
19.8
K.W.
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.6
2.5
2.5
2.5
2.5
2.6
105
T.C.
29.2
31.4
29.4
30.2
33.4
30.9
32.0
28.8
30.6
34.4
32.6
32.6
28.2
31.0
35.3
S.C.
28.8
30.4
23.2
21.8
16.2
30.6
31.4
22.9
22.5
17.7
32.3
32.4
22.6
23.3
19.2
K.W.
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
115
T.C.
27.8
30.0
28.3
29.1
31.9
29.5
30.6
28.4
29.0
32.8
31.2
31.2
28.6
28.8
33.6
S.C.
27.4
29.4
22.6
22.8
16.1
29.1
30.3
23.6
21.9
17.3
30.9
31.2
24.6
21.1
18.6
K.W.
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
125
T.C.
26.3
28.7
27.1
28.1
30.4
28.1
29.3
28.0
27.4
31.2
29.9
29.9
28.9
26.6
31.9
S.C.
25.9
28.4
22.0
23.8
15.9
27.7
29.2
24.3
21.4
17.0
29.6
30.0
26.5
19.0
18.1
K.W.
3.5
3.5
3.5
3.5
3.6
3.5
3.5
3.5
3.5
3.6
3.5
3.5
3.5
3.5
3.6
NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
Air Handler
Coil
T.C.
S.C.
KW
MA12B
FC/MC42B
0.98
0.98
1.00
MA14D
FC/MC48D
1.00
1.00
1.00
MV16C
FC/MC48C
1.02
0.99
0.96
MV20D
FC/MC48D
1.02
0.99
0.96
AV36
–
1.02
0.99
0.96
AHP42
–
1.00
1.00
1.00
–
FC/MC/PC/UC42
0.98
0.98
1.00
–
HC42
1.01
0.98
1.00
–
HD48
1.02
1.02
1.00
Variable Speed
Furnace
Coil
T.C.
S.C.
KW
PV8*B16
FC/MC/PC42B
0.99
0.98
0.96
P(C,V)9*B12
FC/MC/PC42B
0.99
0.98
1.00
PV8*C16
FC/MC/PC42C
0.99
0.98
1.00
PV8*C20
FC/MC/PC42C
0.99
0.98
0.96
P(C,V)9*C16
FC/MC/PC42C
0.99
0.98
1.00
P(C,V)9*C20
FC/MC/PC42C
0.99
0.98
0.96
PV8*C16
FC/MC/PC48C
1.02
1.01
0.96
PV8*C20
FC/MC/PC48C
1.02
1.01
0.96
P(C,V)9*C16
FC/MC/PC48C
1.02
1.01
0.96
P(C,V)9*C20
FC/MC/PC48C
1.02
1.01
0.96
P(C,V)9*D20
FC/MC/PC48D
1.02
1.01
0.96
PV8*C16
HC42
1.02
1.02
0.96
PV8*C20
HC42
1.02
1.02
0.96
P(C,V)9*C16
HC42
1.02
1.02
0.96
P(C,V)9*C20
HC42
1.02
1.02
0.96
PV8*C16
HD48
1.02
1.02
0.96
PV8*C20
HD48
1.02
1.02
0.96
P(C,V)9*C16
HD48
1.02
1.02
0.96
P(C,V)9*C20
HD48
1.02
1.02
0.96
P(C,V)9*D20
HD48
1.02
1.01
0.96