![background image](http://html1.mh-extra.com/html/york/ymb018-thru-060/ymb018-thru-060_technical-manual_4253441021.webp)
246809-YTG-E-0507
Unitary Products Group
21
Multipliers for determining the performance with other indoor section.
HEATING PERFORMANCE DATA
OUTDOOR UNIT MODEL NO.
YMB01811
INDOOR COIL MODEL NO.
FC/MC/PC18
AIR TEMP.
ENTERING
OUTDOOR
UNIT
AIR TEMP.
ENTERING
INDOOR
COIL
ID CFM
450
600
750
MBTUH
KW
C.O.P.
MBTUH
KW
C.O.P.
MBTUH
KW
C.O.P.
60
60
20.3
1.5
4.0
21.2
1.5
4.3
22.1
1.4
4.6
70
19.6
1.6
3.5
20.6
1.6
3.8
21.6
1.5
4.2
80
18.8
1.8
3.1
20.0
1.7
3.4
21.1
1.7
3.7
47
60
17.4
1.4
3.6
18.0
1.4
3.8
18.6
1.4
4.0
70
16.8
1.5
3.2
17.4
1.5
3.4
18.1
1.5
3.6
80
16.1
1.7
2.8
16.9
1.6
3.0
17.6
1.6
3.3
40
60
15.4
1.4
3.3
15.9
1.3
3.5
16.5
1.3
3.6
70
15.1
1.5
3.0
15.6
1.5
3.1
16.2
1.4
3.3
80
14.7
1.6
2.6
15.3
1.6
2.8
16.0
1.6
3.0
30
60
12.0
1.5
2.3
12.5
1.5
2.4
13.1
1.5
2.5
70
12.5
1.4
2.6
12.9
1.4
2.7
13.2
1.4
2.7
80
13.1
1.3
3.0
13.2
1.3
3.0
13.2
1.3
3.0
17
60
9.5
1.4
1.9
10.7
1.4
2.3
12.0
1.3
2.7
70
9.7
1.3
2.1
10.7
1.3
2.4
11.7
1.3
2.7
80
10.0
1.2
2.4
10.7
1.3
2.5
11.4
1.3
2.6
10
60
8.6
1.4
1.8
9.1
1.4
1.9
9.7
1.4
2.0
70
9.2
1.3
2.1
9.6
1.3
2.2
10.0
1.3
2.2
80
9.9
1.2
2.4
10.1
1.2
2.4
10.4
1.2
2.4
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Air Handler
Coil
MBH
KW
COP
MA08B
FC/MC18B
1.00
1.00
1.00
MV12B
FC/MC18B
0.98
1.06
0.92
AV24
–
0.98
1.06
0.92
F*FP024
–
1.00
1.00
1.00
AHP18
–
1.00
1.00
1.00
–
HC18
1.00
1.00
1.00
Variable Speed
Furnace
Coil
T.C.
S.C.
KW
PV8*A12
FC/MC/PC18A
0.97
1.07
0.91
PV9*A12
FC/MC/PC18A
0.98
1.05
0.93
P(C,V)9*B12
FC/MC/PC18B
0.97
1.06
0.91
PV8*A12
HC18
0.97
1.07
0.91
PV9*A12
HC18
0.98
1.05
0.93