Failure type and methods of resolution

In case the following situation, please immediately stop the operation of the air - conditioner and cut off the power supply
then contact distributor.

The RUN light or other display light flashes repidly and keep flashing
 after the plug is taken off and then plugged in.

The fuse blows repeatedly or the circuit breaker is activated repeatedly.

Outside object or water comes into the air-conditioner.

The remote controller does not work or the switch operates unusally.

Other abnormal phenomenon.

Failure
type

In case the following situations, pleasedeal with it according to the following methods, if it does notwork, please
contract distributor and inform the detailed failure.

Failure

Causes

Methods of resolution

start-up
fallure

The wind
blowing
out, but the
cooling/
heating
effect is
bad

The wind 
blowing
out, but it
doesnot
refrigerate

Power supply failure

The power switch is released

The fuse is burnt

The battery is exhusted

it doesn’t reachtheset time for start up

Mistakes in temperature setting

The air filter is blocked by dust

The air inlet or outlet of machine is blocked

The doors or windows are open

The air inlet or outlet of machinels blocked

Compressor has three minutes protection

Mistakes in temperature setting

Wait for the recovery of power supply

Switch on the power

Replace the fuse
Replace the battery

Wait or elim inate the original setting

Set a proper temperature, see the 
methouds of application

Clean the air filter

Remove the obstruction

Close the doors and windows

Remove the obstruction, then restart it 

Wait

Set a proper temperature

Failure code Table

Symptoms

Error code

Error PRI

Communication problem

Indoor PG fan fault

T

 Return wind Sensor error

 T  Indoor pipe Sensor error

 T  Outdoor pipe Sensor error

E5

1

2

3

4

5

E4

E

E3

E2

Summary of Contents for YHCA-YHHA07FSAADK

Page 1: ...and operation Make sure that it is well kept for later reference Read this manual before installation and operation Make sure that it is well kept for later reference High Wall Air Conditioner INSTALL...

Page 2: ...eration tips 14 Troubleshooting guide 17 Please read this installation manualcarefullybeforestarting the installation It will tell you necessary information Quality POLICY Wewillcontinuouslystriveto s...

Page 3: ...lation and maintenance of this air conditioning system should only be car ried out by trained and qualified personnel After unpacking please check the unit carefully for possible damage Before underta...

Page 4: ...louver 6 Vertical louver Inner 7 Air filter 8 Pipe protection ring 9 Drain pipe Outdoor Unit 10 Refrigerant gas liquid piping 11 Service valve 12 Air outlet Indication light and signal receiver Power...

Page 5: ...direction up down The air conditioner automatically adjust the vertical air flow direction in accordance withthe operating mode Note Adjust the vertical air flow direction by remote controller Whenyo...

Page 6: ...BEFORE INSTALLATION Before doing any work check the interior power supply cord and the main breaker capacity are sufficient and the installation area is sufficient and complies with the requirements C...

Page 7: ...n exposure make sure that heat rediation from the condenser is not restricted Don t place animals or plants near the installation location because the cold and hot air out will affect them Make sure t...

Page 8: ...achine to wards the left down and right down side of the installation board until the hangers enters tightly the grooves it produces Click sound Bolt Vertical airflow direction plate Bolt Front frame...

Page 9: ...port or vibration damping should be adopted Installation Outdoor Unit Bolt Air outlet Outdoor Unit Left installation feet Right installation feet Air inlet Pipe Connection Connect the pipe to the indo...

Page 10: ...with tape alongside the wall and fix them to the wall with clips These steps are usually adopted when outdoor unit is installed below the indoor unit In case that you want to have additional drain pip...

Page 11: ...shippedcompletewithachargeofR 22 R407C R410A refrigerant that will be sufficient for an interconnecting piping length of 3 6 meters Liquid Cooling GAS Cooling suction Low pressure High pressure Manifo...

Page 12: ...rew take off the control panel cover from the unit Connect the cable to their terminals according to their number The grounded wire connection 1 loosen the grounded screw of electrical shelf 2 Connect...

Page 13: ...r and disconnect power Remove the batteries from the remote controller 3 The outdoor unit requires periodic maintenance and cleaning Do not attempt to do this yourself Contact your dealer or servicer...

Page 14: ...damage tothe air conditioneror to the other persons safety and property In order to properly use the air conditioner please follow theWorking condition in the instructions otherwise it may activate th...

Page 15: ...its orioiginal position when power is first turned on Dust is blown out from the indoor unit This is a normal condition when the air conditioner has not been used for a long time or during first use o...

Page 16: ...g out but the cooling heating effect is bad The wind blowing out but it doesnot refrigerate Power supply failure The power switch is released The fuse is burnt The battery is exhusted it doesn t reach...

Page 17: ...ool when you started the system 1 Remove charge repair evacuate and recharge 2 Insulate them separately 3 Wait while unit has enough time to cool the room D The compressor runs continuously 1 Thermost...

Page 18: ...e container using a refrigerant reclaim or recovery unit This refrigerant may then be reused if appropriate or returned to the manufacturer for disposal Under No circumstances should refrigerant be ve...

Page 19: ...www johnsoncontrols com Form No 035A00005 000 2009 Johnson Controls Inc Johnson Controls reserve the right to change product features without prior notice...

Reviews: