background image

MAINTENANCE

13

Cleaning the air filter

A clogged air filter reduces the cooling efficiency of this unit. Please clean 
the filter once every 2 weeks.
1. Lift the indoor unit panel up to an angle until it stops with a clicking sound.
2. Take hold of the handle of the AIR FILTER and lift it up slightly to take it 

out from the  filter holder, then pull it downwards.

3. Remove the AIR FILTER from the indoor unit.

• Clean the AIR FILTER once two weeks.
• Clean the AIR FILTER with a vacuum cleaner or water, then dry it up 
   in cool place. 

4. Remove the air freshening  filter from its support frame (The installation 

and removing method of the air freshening  filter is different depending on 

the models, see the pictures marked 

1  and  2  on the left).

• Clean the air freshening filter at least once a month, and replace it 
  every 4-5 months. 

• Clean it with vacuum cleaner, then dry it in cool place.

5. Install the AIR FILTER back into position.
6. Insert the upper portion of the AIR FILTER back into the unit taking care that 

the left and right edges line up correctly and place  filter into position.

Maintenance

If you plan to idle the unit for a long time, perform the following:
(1) Operate the fan for about half a day to dry the inside of the unit.
(2) Stop the air conditioner and disconnect power.
 Remove the batteries from the remote controller.
(3) The outdoor unit requires periodic maintenance and cleaning. Do not 

attempt to do this yourself.

 Contact your dealer or servicer.

Checks before operation

• Check that the wiring is not broken off or disconnected.
• Check that the air   filter is installed.
• Check if the air outlet or inlet is blocked after the air conditioner has not

been used for a long time.

It is necessary to stop the air conditioner and disconnect the power supply
before cleaning.

WARNING

Cleaning the indoor unit and remote controller

• Use a dry cloth to wipe the indoor unit and remote controller.
• A cloth dampened with cold water may be used on the indoor unit if it
  is very dirty. 
• The front panel of the indoor unit can be removed and cleaned with water. 

Then wipe it with a dry cloth.

• Do not use a chemically treated cloth or duster to clean the unit.
• Do not use benzine, thinner, polishing powder, or similar solvents for 

cleaning. These may cause the plastic surface to crack or deform.

CAUTIONS

CAUTIONS

1

2

Air freshening filter

Filter Handle

Air freshening filter

Household

Drain

Cleaner

No

Thinner

• Do not touch the metal parts of the unit when removing the filter. Injuries

can occur when handling sharp metal edges.

• Do not use water to clean inside the air conditioner.

Exposure to water can destroy the insulation, leading to possible electric shock.

• When cleaning the unit,  first make sure that the power and circuit breaker

are turned off.

Summary of Contents for YHCA-YHHA07FSAADK

Page 1: ...and operation Make sure that it is well kept for later reference Read this manual before installation and operation Make sure that it is well kept for later reference High Wall Air Conditioner INSTALL...

Page 2: ...eration tips 14 Troubleshooting guide 17 Please read this installation manualcarefullybeforestarting the installation It will tell you necessary information Quality POLICY Wewillcontinuouslystriveto s...

Page 3: ...lation and maintenance of this air conditioning system should only be car ried out by trained and qualified personnel After unpacking please check the unit carefully for possible damage Before underta...

Page 4: ...louver 6 Vertical louver Inner 7 Air filter 8 Pipe protection ring 9 Drain pipe Outdoor Unit 10 Refrigerant gas liquid piping 11 Service valve 12 Air outlet Indication light and signal receiver Power...

Page 5: ...direction up down The air conditioner automatically adjust the vertical air flow direction in accordance withthe operating mode Note Adjust the vertical air flow direction by remote controller Whenyo...

Page 6: ...BEFORE INSTALLATION Before doing any work check the interior power supply cord and the main breaker capacity are sufficient and the installation area is sufficient and complies with the requirements C...

Page 7: ...n exposure make sure that heat rediation from the condenser is not restricted Don t place animals or plants near the installation location because the cold and hot air out will affect them Make sure t...

Page 8: ...achine to wards the left down and right down side of the installation board until the hangers enters tightly the grooves it produces Click sound Bolt Vertical airflow direction plate Bolt Front frame...

Page 9: ...port or vibration damping should be adopted Installation Outdoor Unit Bolt Air outlet Outdoor Unit Left installation feet Right installation feet Air inlet Pipe Connection Connect the pipe to the indo...

Page 10: ...with tape alongside the wall and fix them to the wall with clips These steps are usually adopted when outdoor unit is installed below the indoor unit In case that you want to have additional drain pip...

Page 11: ...shippedcompletewithachargeofR 22 R407C R410A refrigerant that will be sufficient for an interconnecting piping length of 3 6 meters Liquid Cooling GAS Cooling suction Low pressure High pressure Manifo...

Page 12: ...rew take off the control panel cover from the unit Connect the cable to their terminals according to their number The grounded wire connection 1 loosen the grounded screw of electrical shelf 2 Connect...

Page 13: ...r and disconnect power Remove the batteries from the remote controller 3 The outdoor unit requires periodic maintenance and cleaning Do not attempt to do this yourself Contact your dealer or servicer...

Page 14: ...damage tothe air conditioneror to the other persons safety and property In order to properly use the air conditioner please follow theWorking condition in the instructions otherwise it may activate th...

Page 15: ...its orioiginal position when power is first turned on Dust is blown out from the indoor unit This is a normal condition when the air conditioner has not been used for a long time or during first use o...

Page 16: ...g out but the cooling heating effect is bad The wind blowing out but it doesnot refrigerate Power supply failure The power switch is released The fuse is burnt The battery is exhusted it doesn t reach...

Page 17: ...ool when you started the system 1 Remove charge repair evacuate and recharge 2 Insulate them separately 3 Wait while unit has enough time to cool the room D The compressor runs continuously 1 Thermost...

Page 18: ...e container using a refrigerant reclaim or recovery unit This refrigerant may then be reused if appropriate or returned to the manufacturer for disposal Under No circumstances should refrigerant be ve...

Page 19: ...www johnsoncontrols com Form No 035A00005 000 2009 Johnson Controls Inc Johnson Controls reserve the right to change product features without prior notice...

Reviews: