FORM 201.18-NM7
MATERIAL SAFETY DATA
Section 1 – PRODUCT NAME AND INFORMATION
Product (Trade Name and Synonyms):
YORK “L” Oil
Chemical Name: Ester
Chemical Family: Polyol Ester
Formula:
Proprietary
CAS#:
Proprietary
Section 2
–
COMPONENTS AND HAZARD STATEMENT
This product is non-hazardous.
The product contains no known carcinogens. No special
warning labels are required under OSHA 29 CFR 1910.1200.
Section 3 – SAFE HANDLING AND STORAGE
Handling -
Do not take internally. Avoid contact with skin, eyes, and clothing. Upon contact with skin, wash with
soap and water. Flush eyes with water for 15 minutes and consult physician. Wash contaminated
clothing before reuse.
Storage -
Keep container tightly sealed when not in use. Product is hygroscopic. Storage under nitrogen
highly recommended.
Section 4
–
PHYSICAL DATA
Appearance:
Clear liquid, gray to yellow or light brown tint
Boiling Point:
> 650°F
Vapor Pressure:
<0.01 mmHg @ 20°C
Specific Gravity (water=1):
0.94-0.97
Volatiles, Percent by Volume:
0%
Odor:
Mild, distinct
Solubility in Water:
Negligible
Evaporation Rate (butyl acetate=1): Nil
Section 5 – FIRE AND EXPLOSION HAZARDS
Flash Point (by Cleveland Open Cup): 230-300°C
Flammable Limits:
Not Established
Auto-Ignition Temperature: no data
HMIS Ratings:
Health:
0
Flammability:
1
Reactivity:
0
Extinguishing Media:
Dry chemical; CO
2
foam; water fog (see below)
Unusual Fire and Explosion Hazards: None
Special Fire Fighting Techniques:
Burning fluid may evolve irritating/noxious fumes.
Firefighters should use NIOSH/MNSA-approved self-contained breath-
ing apparatus. Use water fog to cool fire-exposed containers. USE
WATER CAREFULLY NEAR EXPOSED/BURNING LIQUIDS. May
cause frothing and splashing of hot materials.
General Chiller Information & Safety
Summary of Contents for YCAS0098EB
Page 50: ...50 JOHNSON CONTROLS This page intentionally left blank...
Page 61: ...61 JOHNSON CONTROLS FORM 201 18 NM7 This page intentionally left blank 7...
Page 70: ...70 JOHNSON CONTROLS Technical Data FIG 22A CONTROL PANEL COMPONENT LOCATIONS...
Page 71: ...71 JOHNSON CONTROLS FORM 201 18 NM7 LD03280 FIG 22B POWER PANEL COMPONENT LOCATION 7...
Page 72: ...72 JOHNSON CONTROLS Technical Data LEGEND LD03281...
Page 73: ...73 JOHNSON CONTROLS FORM 201 18 NM7 LD03282 LD03283 LD03284 7...
Page 74: ...74 JOHNSON CONTROLS Technical Data CONNECTION DIAGRAM SYSTEM WIRING LD06256 LD03231 LD03232...
Page 75: ...75 JOHNSON CONTROLS FORM 201 18 NM7 COMPRESSOR TERMINAL BOX LD03233 7...
Page 76: ...76 JOHNSON CONTROLS LD03285 Technical Data...
Page 77: ...77 JOHNSON CONTROLS FORM 201 18 NM7 3 4 5 6 3 4 5 6 7 8 5 6 3 4 7 8 9 10 LD06840A 7...
Page 181: ...181 JOHNSON CONTROLS FORM 201 18 NM7 NOTES...
Page 182: ...182 JOHNSON CONTROLS This page intentionally left blank...
Page 183: ...183 JOHNSON CONTROLS FORM 201 18 NM7 This page intentionally left blank...