BAROMETRIC RELIEF DAMPER - This damper accessory
can be used to relieve internal air pressure on units with an
economizer but no power exhaust. This accessory includes a
rain hood, a bird screen and a fully assembled damper. With
bottom duct connections, the damper should be mounted over
the opening in the return air panel. With horizontal ductwork,
the accessory should be mounted on the return air duct.

ECONOMIZER / POWER EXHAUST RAIN HOODS - A rain
hood accessory must be used on units with an economizer, a
motorized damper, or a combined economizer with power
exhaust option. These accessories include all the hood panels,
the necessary components and hardware for field assembly.

SUNLINE 2000

RATINGS

® 

LONG LASTING
POWDER PAINT FINISH

FULL PERIMETER 14 GUAGE BASE
RAILS WITH LIFTING HOLES

NPT

TERMINAL BLOCK
(For Single Point Power Supply
with Electric Heat)
ELECTRIC/ELECTRIC UNITS

ELECTRIC HEATER LOCATION
(OPTIONAL ELECTRIC/ELECTRIC UNITS)

I

20 GAUGE ALUMINIZED STEEL
TUBULAR HEAT EXCHANGERS

ECONOMIZER HOOD

2" DISPOSABLE
FILTERS

OUTDOOR AIR OPENING
FOR SLIDE-IN/PLUG-IN
INTERNAL ECONOMIZER (OPTION)

SIDE AND BOTTOM
SUPPLY & RETURN AIR
DUCT OPENINGS (SIDE X SIDE)

1" NPTI
CONDENSATE DRAIN

BELT-DRIVE
BLOWER MOTOR

POWER VENTOR MOTOR
WITH POST PURGE CYCLE

HOLE FOR BOTTOM
GAS SUPPLY ENTRY

KNOCKOUTS FOR SIDE
GAS SUPPLY ENTRY

BOTTOM POWER & CONTROL
WIRING ENTRY

KNOCKOUT FOR
SIDE POWER WIRING ENTRY SIDE

KNOCKOUT FOR
SIDE CONTROL WIRING ENTRY

ELECTRICAL DISCONNECT
MOUNTING LOCATION
(Field installed)

LOW VOLTAGE RELAY BOARD
AND TERMIANL STRIP

COPPER TUBE/ALUMINUM FIN
CONDENSER COILS 

HIGH EFFICIENCY COMPRESSORS
WITH CRANKCASE HEATERS

GAS/ELECTRIC

UNIT SHOWN

CAPACITY RATINGS – COOLING

MODEL

RATING POINT

TOTAL OUTPUT,

kW/MBH

TOTAL INPU,T

kW

COP

EER

ELECTRIC HEAT

Nominal Capacity,

kW

300

T1

85.2 / 293

35.4

2.4

8.3

18, 36, 54, 72

T2

74.4 / 254

38.7

1.9

6.6

18, 36, 54, 72

T3

79.9 / 273

31.7

2.5

8.6

18, 36, 54, 72

CAPACITY RATINGS – GAS HEAT

MODEL

RATING POINT

TOTAL OUTPUT,

kW/MBH

TOTAL INPUT,

kW

COP

EER

GAS HEAT RATINGS

MBH INPUT

MBH OUTPUT

300

T1

85.2 / 293

35.4

2.4

8.3

300

240

T2

74.4 / 254

38.7

1.9

6.6

T3

79.9 / 273

31.7

2.5

8.6

530.26-TG4YI

Unitary Products Group

3

Summary of Contents for Sunline 2000

Page 1: ...e mounted over the opening in the return air panel With horizontal ductwork it should be mounted on the return air duct All supply air blowers are equipped with a belt drive that can be adjusted to me...

Page 2: ...a field installed option DUAL INPUT ELECTRONIC ENTHALPY ECONOMIZERS Includes a slide in plug in damper assembly with fully modulating spring return monitor actuator capable of introducing up to 100 ou...

Page 3: ...LAR HEAT EXCHANGERS ECONOMIZER HOOD 2 DISPOSABLE FILTERS OUTDOOR AIR OPENING FOR SLIDE IN PLUG IN INTERNAL ECONOMIZER OPTION SIDE AND BOTTOM SUPPLY RETURN AIR DUCT OPENINGS SIDE X SIDE 1 NPTI CONDENSA...

Page 4: ...6 87 6 28 5 88 83 78 65 80 9 32 0 81 76 71 62 Air On Evaporator Coil Temperature of Air on Condenser Coil OD Dry Bulb 80 F OD Dry Bulb 95 F OD Dry Bulb 115 F Total Cap MBH Power Input KW Sensible Capa...

Page 5: ...the supply and return air duct system All internal unit resistances have been deducted from the total static pressure of the blower Do NOT close the pulley below 1 turn open Factory setting MODEL SIZE...

Page 6: ...INS PER 25mm 1 in 15 FACE AREA m2 Ft 2 4 02 43 3 COMPRESSOR Qty Per Unit TANDEM 8 TON NOMINAL CAPACITY 3 AIR FILTERS QUANTITY PER UNIT 406 x 508 x 51 mm 2 16 x 20 x 2 in QUANTITY PER UNIT 406 x 635 x...

Page 7: ...FIELD WIRING DCE DCG Electric Electric and Gas Electric Units 530 26 TG4YI Unitary Products Group 7...

Page 8: ...between any combustible material and the supply air ductwork for a distance of 3 feet from the unit The products of combustion must not be allowed to accumulate within a confined space and recirculat...

Page 9: ...cting side ducts For bottom duct applications 1 Remove the side panels from the supply and return air compartments to gain access to the bottom supply and return air duct covers 2 Remove and discard t...

Page 10: ...S 3207 126 1 4 Supply and Return Air including duct support rails as shown are typical for downflow duct applications For location of sideflow duct applications on back of unit refer to Unit Dimension...

Page 11: ...TYPICAL APPLICATIONS TYPICAL ROOF TOP INSTALLATION GAS ELECTRIC UNIT SHOWN 530 26 TG4YI Unitary Products Group 11...

Page 12: ...p P O Box 1592 York Pennsylvania USA 17405 1592 Subject to change without notice Printed in U S A Copyright by York International Corporation 1996 All Rights Reserved Code EBY EGY 530 26 TG4YI Superce...

Reviews: