background image

UNIT DIMENSIONS - CONT’D. - 

(DCE / DCG)

CENTER OF GRAVITY

3338 (136-1/4"(

1078
(44")

1376
(56")

2254
(92")

SUPPLY
AIR

RETURN 
AIR

OUTDOOR
AIR

5-1/8"

18-5/8"

27-3/4"

29-5/8" (15 TON)
39-5/8" (20 TON)

40-1/2"

OUTDOOR AIR
COMPARTMENT
ACCESS

FILTER 
ACCESS

1" NPT FEMALE
COND. DRAIN
CONNECTION

DOT PLUG
(For pressure
drop reading)

EVAPORATOR
SECTION

CONDENSER
SECTION

GAUGE LINE
ACCESS

40-3/8"

5-1/2"

COMPRESSOR
ACCESS

SUPPLY AIR
ACCESS

RETURN AIR
ACCESS

REAR

VIEW

DETAIL “X”

ACCESSORY SIDE SUPPLY AND RETURN AIR OPENINGS

DUCT COVERS - Units are shipped with the bottom
duct openings covered. An accessory flange kit is
available for connecting side ducts.
For bottom duct applications:
1. Remove the side panels from the supply and return
    air compartments to gain access to the bottom
    supply and return air duct covers.
2. Remove and discard the bottom duct covers. (Duct
    openings are closed with sheet metal covers except
    when the unit includes a power exhaust option. The
    covering consists of a heavy black paper composition.)
3. Replace the side supply and return air compartment
    panels.
For side duct applications;
1. Replace the side panels on the supply and return air
    compartments with the accessory flange kit panels.
2. Connect ductwork to the duct flanges on the rear of
    the unit.

 

     39-5/8

397

15

5

8

610 (24") (180)
889 (35") (240)

870

(34-1/4")

ECONOMIZER / MOTORIZED DAMPER
RAIN HOOD

DETAIL “Y”

UNIT WITH RAIN HOOD

530.26-TG4YI

Unitary Products Group

9

Summary of Contents for Sunline 2000

Page 1: ...e mounted over the opening in the return air panel With horizontal ductwork it should be mounted on the return air duct All supply air blowers are equipped with a belt drive that can be adjusted to me...

Page 2: ...a field installed option DUAL INPUT ELECTRONIC ENTHALPY ECONOMIZERS Includes a slide in plug in damper assembly with fully modulating spring return monitor actuator capable of introducing up to 100 ou...

Page 3: ...LAR HEAT EXCHANGERS ECONOMIZER HOOD 2 DISPOSABLE FILTERS OUTDOOR AIR OPENING FOR SLIDE IN PLUG IN INTERNAL ECONOMIZER OPTION SIDE AND BOTTOM SUPPLY RETURN AIR DUCT OPENINGS SIDE X SIDE 1 NPTI CONDENSA...

Page 4: ...6 87 6 28 5 88 83 78 65 80 9 32 0 81 76 71 62 Air On Evaporator Coil Temperature of Air on Condenser Coil OD Dry Bulb 80 F OD Dry Bulb 95 F OD Dry Bulb 115 F Total Cap MBH Power Input KW Sensible Capa...

Page 5: ...the supply and return air duct system All internal unit resistances have been deducted from the total static pressure of the blower Do NOT close the pulley below 1 turn open Factory setting MODEL SIZE...

Page 6: ...INS PER 25mm 1 in 15 FACE AREA m2 Ft 2 4 02 43 3 COMPRESSOR Qty Per Unit TANDEM 8 TON NOMINAL CAPACITY 3 AIR FILTERS QUANTITY PER UNIT 406 x 508 x 51 mm 2 16 x 20 x 2 in QUANTITY PER UNIT 406 x 635 x...

Page 7: ...FIELD WIRING DCE DCG Electric Electric and Gas Electric Units 530 26 TG4YI Unitary Products Group 7...

Page 8: ...between any combustible material and the supply air ductwork for a distance of 3 feet from the unit The products of combustion must not be allowed to accumulate within a confined space and recirculat...

Page 9: ...cting side ducts For bottom duct applications 1 Remove the side panels from the supply and return air compartments to gain access to the bottom supply and return air duct covers 2 Remove and discard t...

Page 10: ...S 3207 126 1 4 Supply and Return Air including duct support rails as shown are typical for downflow duct applications For location of sideflow duct applications on back of unit refer to Unit Dimension...

Page 11: ...TYPICAL APPLICATIONS TYPICAL ROOF TOP INSTALLATION GAS ELECTRIC UNIT SHOWN 530 26 TG4YI Unitary Products Group 11...

Page 12: ...p P O Box 1592 York Pennsylvania USA 17405 1592 Subject to change without notice Printed in U S A Copyright by York International Corporation 1996 All Rights Reserved Code EBY EGY 530 26 TG4YI Superce...

Reviews: