TYPICAL APPLICATIONS

TYPICAL ROOF-TOP INSTALLATION
    (GAS/ELECTRIC UNIT SHOWN)

530.26-TG4YI

Unitary Products Group

11

Summary of Contents for Sunline 2000

Page 1: ...e mounted over the opening in the return air panel With horizontal ductwork it should be mounted on the return air duct All supply air blowers are equipped with a belt drive that can be adjusted to me...

Page 2: ...a field installed option DUAL INPUT ELECTRONIC ENTHALPY ECONOMIZERS Includes a slide in plug in damper assembly with fully modulating spring return monitor actuator capable of introducing up to 100 ou...

Page 3: ...LAR HEAT EXCHANGERS ECONOMIZER HOOD 2 DISPOSABLE FILTERS OUTDOOR AIR OPENING FOR SLIDE IN PLUG IN INTERNAL ECONOMIZER OPTION SIDE AND BOTTOM SUPPLY RETURN AIR DUCT OPENINGS SIDE X SIDE 1 NPTI CONDENSA...

Page 4: ...6 87 6 28 5 88 83 78 65 80 9 32 0 81 76 71 62 Air On Evaporator Coil Temperature of Air on Condenser Coil OD Dry Bulb 80 F OD Dry Bulb 95 F OD Dry Bulb 115 F Total Cap MBH Power Input KW Sensible Capa...

Page 5: ...the supply and return air duct system All internal unit resistances have been deducted from the total static pressure of the blower Do NOT close the pulley below 1 turn open Factory setting MODEL SIZE...

Page 6: ...INS PER 25mm 1 in 15 FACE AREA m2 Ft 2 4 02 43 3 COMPRESSOR Qty Per Unit TANDEM 8 TON NOMINAL CAPACITY 3 AIR FILTERS QUANTITY PER UNIT 406 x 508 x 51 mm 2 16 x 20 x 2 in QUANTITY PER UNIT 406 x 635 x...

Page 7: ...FIELD WIRING DCE DCG Electric Electric and Gas Electric Units 530 26 TG4YI Unitary Products Group 7...

Page 8: ...between any combustible material and the supply air ductwork for a distance of 3 feet from the unit The products of combustion must not be allowed to accumulate within a confined space and recirculat...

Page 9: ...cting side ducts For bottom duct applications 1 Remove the side panels from the supply and return air compartments to gain access to the bottom supply and return air duct covers 2 Remove and discard t...

Page 10: ...S 3207 126 1 4 Supply and Return Air including duct support rails as shown are typical for downflow duct applications For location of sideflow duct applications on back of unit refer to Unit Dimension...

Page 11: ...TYPICAL APPLICATIONS TYPICAL ROOF TOP INSTALLATION GAS ELECTRIC UNIT SHOWN 530 26 TG4YI Unitary Products Group 11...