120
YORK INTERNATIONAL
This message informs the operator if SYS 1 Run Per-
missive (flow switch, remote START/STOP) was in the
RUN mode (ON/closed) or “STOP” mode (OFF/open).
This message indicates whether Compressor 2 was ON
or OFF at the time of the fault.
This message shows the Run Time logged on SYS 2,
since the last start, in Days (D), Hours (H), Minutes (M),
and Seconds (S).
This message indicates SYS 2 % FLA and Average Mo-
tor Current at the time of the fault.
This message shows SYS 2 % FLA Motor Current in
Phase L1 at the time of the fault.
This message shows SYS 2 % FLA Motor Current in
Phase L2 at the time of the fault.
This message shows SYS 2 % FLA Motor Current in
Phase L3 at the time of the fault.
This display shows the Oil Pressure of SYS 2 at the
time of the fault.
This display shows the Suction Pressure of SYS 2 at
the time of the fault.
This message indicates the Saturated Suction Tempera-
ture of SYS 2 at the time of the fault.
This message indicates SYS 2 Suction Line Tempera-
ture at the time of the fault.
This message indicates SYS 2 superheat at the time of
the fault.
This message indicates SYS 2 Discharge Pressure at
the time of the fault.
This message indicates SYS 2 Saturated Discharge Tem-
perature at the time of the fault.
This message indicates SYS 2 Discharge Gas Tempera-
ture in the oil separator at the time of the fault.
This display shows the Oil Temperature of SYS 2 at time
of the fault.
S Y S
1
R U N
P E R M I S S I V E
O N
S Y S
2
C O M P R E S S O R
O N
S Y S
2
R U N
T I M E
0 -
0 -
2 - 4 7
D - H - M - S
S Y S
2
A V G
M O T O R
A M P S
1 0 0
% F L A
9 0
A M P S
S Y S
2
P H A S E
L 1
9 9
% F L A
8 9
A M P S
S Y S
2
P H A S E
L 2
9 9
% F L A
8 9
A M P S
S Y S
2
P H A S E
L 3
9 9
% F L A
8 9
A M P S
S Y S
2
O I L
P R E S S U R E
1 0
P S I D
S Y S
2
S U C T I O N
P R E S S
5 9
P S I G
S Y S
2
S A T
S U C T
T E M P
3 4 . 3
° F
S Y S
2
S U C T I O N
T E M P
4 4 . 1
° F
S Y S
2
S U P E R H E A T
1 2 . 5
° F
S Y S
2
D S C H
P R E S S
2 2 7
P S I G
S Y S
2
S A T
D S C H
T E M P
6 5 . 2
° F
S Y S
2
D I S C H A R G E
T E M P
1 8 7 . 2
° F
S YS
2
O I L
T E M P
1 4 7 . 8
° F
Summary of Contents for Millennium YCAS 316
Page 11: ...FORM 201 10 NM1 11 YORK INTERNATIONAL YCAS 140 246 DIMENSIONS English LD01444 LD01446...
Page 13: ...FORM 201 10 NM1 13 YORK INTERNATIONAL YCAS 140 246 DIMENSIONS SI LD01440 LD01442...
Page 15: ...FORM 201 10 NM1 15 YORK INTERNATIONAL YCAS 216X 266X DIMENSIONS English LD01454 LD01454...
Page 17: ...FORM 201 10 NM1 17 YORK INTERNATIONAL YCAS 216X 266X DIMENSIONS SI LD01450 LD01448...
Page 33: ...FORM 201 10 NM1 33 YORK INTERNATIONAL 28514A FILTER DRYER LIQUID STOP VALVE...
Page 37: ...FORM 201 10 NM1 37 YORK INTERNATIONAL LD01285 FIG 3 SCREW CHILLER REFIGERANT FLOW DIAGRAM...
Page 59: ...FORM 201 10 NM1 59 YORK INTERNATIONAL FIG 11 CONTINUED LD01465 D...
Page 61: ...FORM 201 10 NM1 61 YORK INTERNATIONAL FIG 12 CONTINUED LD01458 D...
Page 69: ...FORM 201 10 NM1 69 YORK INTERNATIONAL FIG 16 CONTINUED LD01206 D...
Page 71: ...FORM 201 10 NM1 71 YORK INTERNATIONAL FIG 17 CONTINUED LD01202 D...