86
GLOBAL
INDUSTRIES, INC.
M36 - M48 Bucket Elevator
10230004
2015-08-31
Assembly
1g) Punch Holes
1h) Torque Bolts
5) Clamp belt ends together securely. Use the
punched belt end as a template. Mark and
punch (or drill) holes in the other belt end (1g).
6) Assemble the Dura-Splice units into the belt
(1i) and tighten all bolts to 75 foot-pounds with
a torque wrench. (This is important to insure
maximum splice strength.)
7) After 15 minutes, re-tighten all bolts again to
75 foot-pounds.
8) Your Dura-Splice is complete! You have just
installed a super-strong elevator splice that
will offer many years of service with minimum
maintenance.
1i) Assemble the Splice Clamp Set
1j) Completed Splice Clamp Set