33
6.1.2 Micro-Switch Introduce
:
YKKE12BXTMCM-RX
,
YKJE12BXTMCM-RX, YKKE18BXTMCM-RX
,
YKJE18BXTMCM-RX,
A. Micro-switch SW1 is for selection of indoor fan stop temperature (TEL0) when it is in anti-cold wind
action in heating mode.
Range: 24
o
C, 15
o
C, 8
o
C, according to EEROM setting (reserved for special customizing).
T 2
S e ttin g fa n s p e e d
H
M +
M
L
S u p e r s lo w
F a n o ff
T E L 0
+ 1 6
T E L 0
+ 1 4
T E L 0
+ 1 2
T E L 0
+ 1 0
T E L 0
+ 8
T E L 0
+ 6
T E L 0
+ 1 2
T E L 0
+ 1 0
T E L 0
+ 8
T E L 0
+ 6
T E L 0
+ 4
T E L 0
B. Micro-switch SW2 is for selection of indoor FAN ACTION if room temperature reaches the setponit
and the compressor stops.
Range: OFF (in 127s), Keep running.
C. Micro-switch SW3 is for selection of auto-restart function.