16.4.20 Communication Malfunction between Indoor Unit and auto-lifting Panel (F7)
Malfunction decision conditions
Indoor PCB does not get the feedback from the PCB of auto
lifting-panel
Possible causes
●
Wiring mistake between indoor PCB and
auto-lifting panel
●
Faulty PCB of auto-lifting panel
●
Faulty indoor PCB
Communication malfunction between indoor
unit and auto-lifting panel
NO
Replace the indoor main PCB
is it in working order?
YES
Has the problem been solved?
Check the wire connection between auto-
lifting panel and indoor unit
Replace the main control of auto-lifting panel.
Correct the connection
NO