036-21335-003-B-0206
18
Unitary Products Group
TABLE 19: FAN PERFORMANCE DATA - 25 TON
1
RPM
CFM
8,
000
9,
000
10,
000
11,
000
12,
000
SP
2
BHP
3
K
W
SP
2
BHP
3
K
W
SP
2
BHP
3
K
W
SP
2
BHP
3
K
W
SP
2
BHP
3
K
W
600
-
-
-
0.30
2.5
2.3
0.20
3.1
2.9
0.02
3.6
3.4
-
-
-
635
0.56
2.4
2.3
0.43
2.7
2.6
0.31
3.3
3.1
0.13
3.8
3.5
-
-
-
700
0.80
3.0
2.8
0.68
3.3
3.1
0.54
3.7
3.5
0.38
4.2
3.9
0.20
4.8
4.5
775
1.12
3.7
3.4
1.00
4.0
3.7
0.85
4.4
4.1
0.70
4.8
4.5
0.54
5.3
5.0
800
1.23
3.9
3.7
1.11
4.3
4.0
0.97
4.7
4.4
0.82
5.1
4.8
0.66
5.6
5.2
875
1.60
4.8
4.5
1.48
5.1
4.8
1.34
5.6
5.2
1.19
6.0
5.7
1.04
6.6
6.2
900
1.73
5.1
4.8
1.61
5.5
5.1
1.47
5.9
5.5
1.33
6.4
6.0
1.17
7.0
6.5
940
1.95
5.6
5.2
1.82
6.0
5.6
1.70
6.5
6.1
-
-
-
-
-
-
1.
Unit resistance is based on a dry evaporator coil and clean filters.
2.
Available static pressure in I
WG to overcome the resistance of the duct system and any accessories added to the unit. Refer to
the blower motor and drive table and the accessory static resistance table for additional information.
3.
Motors can be selected to operate into the service factor because they are located in the moving air stream, upstream of any heat-
ing device. units with steam or hot water coils are the only exception. On these units, the BHP must not exceed the nominal HP
rating of the motor.
TABLE 20: FAN PERFORMANCE DATA - 30 TON
1
RPM
CFM
10,
000
11,
000
12,
000
13,
000
14,
000
SP
2
BHP
3
K
W
SP
2
BHP
3
K
W
SP
2
BHP
3
K
W
SP
2
BHP
3
K
W
SP
2
BHP
3
K
W
600
0.20
3.1
2.9
0.02
3.6
3.4
-
-
-
-
-
-
-
-
-
635
0.31
3.3
3.1
0.13
3.8
3.5
-
-
-
-
-
-
-
-
-
700
0.54
3.7
3.5
0.38
4.2
3.9
0.20
4.8
4.5
0.03
5.3
5.0
-
-
-
775
0.85
4.4
4.1
0.70
4.8
4.5
0.54
5.3
5.0
0.39
5.8
5.5
0.20
6.4
6.0
800
0.97
4.7
4.4
0.82
5.1
4.8
0.66
5.6
5.2
0.52
6.1
5.7
0.35
6.7
6.3
875
1.34
5.6
5.2
1.19
6.0
5.7
1.04
6.6
6.2
0.93
7.1
6.6
0.77
7.7
7.2
900
1.47
5.9
5.5
1.33
6.4
6.0
1.17
7.0
6.5
1.07
7.5
7.0
0.90
8.2
7.6
940
1.70
6.5
6.1
1.55
7.0
6.6
1.40
7.7
7.2
1.31
8.3
7.8
1.09
9.0
8.4
1.
Unit resistance is based on a dry evaporator coil and clean filters.
2.
Available static pressure in I
WG to overcome the resistance of the duct system and any accessories added to the unit. Refer to
the blower motor and drive table and the accessory static resistance table for additional information.
3.
Motors can be selected to operate into the service factor because they are located in the moving air stream, upstream of any heat-
ing device. units with steam or hot water coils are the only exception. On these units, the BHP must not exceed the nominal HP
rating of the motor.
http://www.rezine.net
Page 200
Summary of Contents for HA090
Page 42: ...http www rezine net Page 42 ...
Page 59: ...http www rezine net Page 59 ...
Page 60: ...http www rezine net Page 60 ...
Page 63: ...http www rezine net Page 63 ...
Page 70: ...http www rezine net Page 70 ...
Page 97: ...http www rezine net Page 97 ...
Page 98: ...http www rezine net Page 98 ...
Page 100: ...http www rezine net Page 100 ...
Page 103: ...http www rezine net Page 103 ...
Page 110: ...http www rezine net Page 110 ...
Page 158: ...http www rezine net Page 158 ...
Page 166: ...http www rezine net Page 166 ...
Page 167: ...http www rezine net Page 167 ...
Page 169: ...http www rezine net Page 169 ...
Page 172: ...http www rezine net Page 172 ...
Page 179: ...http www rezine net Page 179 ...
Page 182: ...http www rezine net Page 182 ...
Page 206: ...http www rezine net Page 206 ...
Page 207: ...http www rezine net Page 207 ...
Page 209: ...http www rezine net Page 209 ...
Page 212: ...http www rezine net Page 212 ...
Page 219: ...http www rezine net Page 219 ...
Page 222: ...http www rezine net Page 222 ...