036-21365-003-D-1105
Unitary Products Group
3
TABLE 1: ARI RATINGS
1
CONDENSING
UNIT MODEL
INDOOR BLOWER UNIT
MODEL
SYSTEM
MBH
SYSTEM EER
CONDENSING UNIT
SOUND
LEVEL
2
(DB)
HA120
LA120
126
3
10.53
88.0
1
Certified in accordance with Unitary Large Equipment certification program, which is based on ARI Standard 340/
360.
2
Rated in accordance with ARI Standard 270.
3
Deduct 1.0 MBH for units operating at 208 volts.
TABLE 2: UNIT APPLICATION DATA
Voltage Variation
1
Min. / Max.
1
Utilization range “A” in accordance with ARI Standard
110.
208/230-3-60
187 / 252
460-3-60
432 / 504
575-3-60
540 / 630
Ambient Air on Condenser Coil
Min. / Max.
35 ºF
2
/ 125 ºF
2
The minimum allowed ambient temperature for
mechanical cooling without the head pressure control
accessory installed must be raised if the indoor air flow
is less than the minimum value given in the capacity
tables.
Ambient Air on Condenser Coil
Min. / Max. with Head Pressure Control
0 - 125 ºF
TABLE 3: PHYSICAL DATA
Model
Size
(Mbh)
Compressor
1
Condenser
Unit
Weight
(Lbs.)
Charge,
(Refrigerant-22)
Lbs,-Oz.
24” Fan (Propeller)
Fan Motor
2
Coil
Rating
(Tons)
Cap.
(Stg’s)
Qty.
Blades/
Pitch
(Deg.)
Nom
CFM
Pitch
(Deg.)
Qty. HP RPM
Rotation**
Fins
per
inch
Rows
Deep
Ship. Oper. Holding
3
Oper.
4
HA120
10
1
2
3/26
8100
26
2
3/4
1110
CW
20
2
731
741
2 - 0
27.85
1
Consists of one scroll compressor.
2
The ball bearing, 48 frame, single phase condenser fan motor have internal protection are directly connected to the condenser fans.
3
Holding charge is the amount in the unit as shipped from the factory.
4
Operating refrigerant charge is for the condensing unit and the matching York air handler, but does not include the charge in the
interconnecting piping.
See the Refrigerant Line Charge Table to determine the additional refrigerant charge required for interconnecting piping.
** When viewing the shaft end of the motor.
http://www.rezine.net
Page 17
Summary of Contents for HA090
Page 42: ...http www rezine net Page 42 ...
Page 59: ...http www rezine net Page 59 ...
Page 60: ...http www rezine net Page 60 ...
Page 63: ...http www rezine net Page 63 ...
Page 70: ...http www rezine net Page 70 ...
Page 97: ...http www rezine net Page 97 ...
Page 98: ...http www rezine net Page 98 ...
Page 100: ...http www rezine net Page 100 ...
Page 103: ...http www rezine net Page 103 ...
Page 110: ...http www rezine net Page 110 ...
Page 158: ...http www rezine net Page 158 ...
Page 166: ...http www rezine net Page 166 ...
Page 167: ...http www rezine net Page 167 ...
Page 169: ...http www rezine net Page 169 ...
Page 172: ...http www rezine net Page 172 ...
Page 179: ...http www rezine net Page 179 ...
Page 182: ...http www rezine net Page 182 ...
Page 206: ...http www rezine net Page 206 ...
Page 207: ...http www rezine net Page 207 ...
Page 209: ...http www rezine net Page 209 ...
Page 212: ...http www rezine net Page 212 ...
Page 219: ...http www rezine net Page 219 ...
Page 222: ...http www rezine net Page 222 ...