TABLE 10: PHYSICAL DATA (OUTDOOR UNIT)
DESCRIPTION
UNIT MODEL - EA090
Compressor
1
Rating - tons
7-1/2
Fans
Quantity
2
Diameter - inches No. of Blades
24/3
Nominal CFM
7800
Fan Motors
2
HP
3/4
RPM
1100
Coil
Rows Deep x Rows High
2 x 36
Finned Length - inches
96
Face Area - square feet
24.00
Tube (Copper) OD - inches
3/8
Fins (Aluminum) per inch
16
Refrigerant-22 (Lbs.)
Holding Charge
1.50
Operating Charge
3
18.8
Pumpdown Capacity
4
24.6
Unit Weight (Lbs.)
Shipping
510
Operating
505
1
These compressors are fully hermetic.
2
These PSC motors are directly connected to the outdoor fans and have inherent protection, ball bearings and a 48 frame. Rotation
(when viewing shaft end of motor) -090 = CW.
3
Includes outdoor unit and matched indoor blower unit, but no piping.
4
Based on a 95 ºF ambient.
TABLE 11: PHYSICAL DATA (INDOOR UNIT)
DESCRIPTION
UNIT MODEL - FA090
Coil
Rows Deep x Rows High
3 x 32
Finned Length - inches
45.5
Face Area - square feet
10.1
Tube (Copper) OD - inches
3/8
Fins (Aluminum) per inch
13
Centrifugal Blower (Forward Curve)
Diameter x Width - inches
15 X 15
Blower Motor
1
Nominal Rating - HP
1-1/2
Filters (Throwaway)
Quantity Per Unit - 16” x 25” x 1”
4
Total Face Area - square feet
11.1
Refrigerant-22 (Lbs.)
Holding Charge
2
-
Pumpdown Capacity
3
16.5
Unit Weight
4
(lbs.)
Shipping
425
Operating
385
Accessory Operating Weights (Lbs.)
Electric Heaters
5
10 KW
63
16 KW
66
26 KW
71
36 KW
74
Supply Air Plenum
102
Base
60
Return Air Grille
15
Shipping Volume (Basic Unit) - cubic feet
45
1
All of these 1750 RPM motors have a solid base, a 56 frame, a 1.15 service factor, inherent protection & permanently lubricated
ball bearings. Refer to Table 7 for additional motor & drive data.
2
Although every indoor unit is shipped with a small holding charge, this charge will be lost during installation. Loss of all refrigerant
must be reclaimed during installation - NOT vented into the atmosphere. Refer to the above table on the OUTDOOR unit for the
system operating charge.
3
Based on a 80ºF ambient.
4
Refer to Installation Instruction Form 035-18475-000 for the distributed weight of these indoor units.
5
Refer to Table 13 for additional electric heat accessory data.
http://www.rezine.net
Page 39
Summary of Contents for HA090
Page 42: ...http www rezine net Page 42 ...
Page 59: ...http www rezine net Page 59 ...
Page 60: ...http www rezine net Page 60 ...
Page 63: ...http www rezine net Page 63 ...
Page 70: ...http www rezine net Page 70 ...
Page 97: ...http www rezine net Page 97 ...
Page 98: ...http www rezine net Page 98 ...
Page 100: ...http www rezine net Page 100 ...
Page 103: ...http www rezine net Page 103 ...
Page 110: ...http www rezine net Page 110 ...
Page 158: ...http www rezine net Page 158 ...
Page 166: ...http www rezine net Page 166 ...
Page 167: ...http www rezine net Page 167 ...
Page 169: ...http www rezine net Page 169 ...
Page 172: ...http www rezine net Page 172 ...
Page 179: ...http www rezine net Page 179 ...
Page 182: ...http www rezine net Page 182 ...
Page 206: ...http www rezine net Page 206 ...
Page 207: ...http www rezine net Page 207 ...
Page 209: ...http www rezine net Page 209 ...
Page 212: ...http www rezine net Page 212 ...
Page 219: ...http www rezine net Page 219 ...
Page 222: ...http www rezine net Page 222 ...