Standard Features
Construction
• ARI 880 certified and labeled
• 22-gauge galvanized steel casing and valve
• G90 galvanized steel
• 1/2”, 4lb/ft
3
skin, dual density fiberglass insulation, glued
and clinch-pinned in place
Hot Water Coils
• ARI 410 certified and labeled
• 1-, 2-, 3-, 4-row coils
• Tested at a minimum of 350 psig under water
• Mechanically expanded copper tubes leak tested
to 350 psig air pressure
• Male sweat type water connections
Primary Air Valve
• Embossed rigidity rings
• Low-thermal conducting damper shaft with
position indicator
• Mechanical stops for open and closed position
• Multi-point center-averaging airflow sensor
• Brass balancing tees
• Plenum-rated sensor tubing
Electrical Components
• cETL listed for safety compliance
• National Electrical Manufacturers Association (NEMA)
Type 1 wiring enclosure
Electric Heat
• ETL listed as an assembly for safety compliance
• Integral electric heat assembly
• Automatic reset primary and back-up secondary
thermal limits
• Single-point power connection
• Hinged electrical enclosure
• Fusing per NEC
• Airflow switch
• Ni-chrome elements
• Primary/Secondary power terminations
• Wiring diagram
Optional Features
Construction
• 20-gauge galvanized steel construction
• 3/4” or 1” fiberglass insulation
• Scrim-reinforced, foil-faced insulation meeting American
Society for Testing and Materials (ASTM) C1136 for mold,
mildew, and humidity resistance
•
1/2” Elastomeric closed-cell foam insulation
• Double wall construction with 22-gauge liner
• Mounting brackets to accept all-thread hanging rods or
wire hangers
• Low temperature construction for use in thermal storage
applications, including a thermally isolated primary air
inlet and a composite damper shaft
Hot Water Coils
• Low pressure steam coils
• Multi-circuit coils for reduced water pressure drop
• Opposite hand water connections
• Bottom and top access plates for cleaning
Electrical Components
• Full unit toggle disconnect and inline motor fusing
• Primary and secondary transformer fusing
Electric Heat
• Proportional solid state relay (SSR) heater control
• Mercury contactors
• Door interlocking disconnect switches
• Disconnect (toggle or door interlocking)
• Pneumatic Electric (PE) switches
• Mercury and magnetic contactors
• Manual reset secondary limit
• 24 volt control transformer
• Special watt densities
• Finned tubular elements
Controls
• Factory-provided controls
• Direct digital controls (DDC) for N2 or LON
®
networks
• Pneumatic controls
© 2005 Johnson Controls, Inc.
P.O. Box 423, Milwaukee, WI 53201
Printed in USA PUBL-3888
www.johnsoncontrols.com
TSS – Single Duct Variable Air Volume Terminal
http://www.rezine.net
Page 105
Summary of Contents for HA090
Page 42: ...http www rezine net Page 42 ...
Page 59: ...http www rezine net Page 59 ...
Page 60: ...http www rezine net Page 60 ...
Page 63: ...http www rezine net Page 63 ...
Page 70: ...http www rezine net Page 70 ...
Page 97: ...http www rezine net Page 97 ...
Page 98: ...http www rezine net Page 98 ...
Page 100: ...http www rezine net Page 100 ...
Page 103: ...http www rezine net Page 103 ...
Page 110: ...http www rezine net Page 110 ...
Page 158: ...http www rezine net Page 158 ...
Page 166: ...http www rezine net Page 166 ...
Page 167: ...http www rezine net Page 167 ...
Page 169: ...http www rezine net Page 169 ...
Page 172: ...http www rezine net Page 172 ...
Page 179: ...http www rezine net Page 179 ...
Page 182: ...http www rezine net Page 182 ...
Page 206: ...http www rezine net Page 206 ...
Page 207: ...http www rezine net Page 207 ...
Page 209: ...http www rezine net Page 209 ...
Page 212: ...http www rezine net Page 212 ...
Page 219: ...http www rezine net Page 219 ...
Page 222: ...http www rezine net Page 222 ...