TECHNICAL GUIDE
®
SPLIT-SYSTEM
HEAT PUMPS
60 HZ
EA120 / FA120
This product was manufactured
in a plant whose quality system
is certified/registered as being
in conformity with ISO 9001.
036-21363-002-B-0303
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
DESCRIPTION
YORK has combined the latest concepts in modern technology
with time-proven quality standards to design a split-system heat
pump to meet the demands of the energy and quality-conscious
commercial market.
Both the outdoor and indoor units are completely piped and wired
at the factory. Only the interconnecting liquid and vapor lines are
required to complete the refrigerant circuit. Every unit is dehy-
drated, evacuated, leak tested and pressure tested before being
pressurized with a holding charge of Refrigerant-22 for shipment
and/or storage. The compressor, fan motors and controls are
functionally tested after the units are fabricated to assure a reli-
able start-up and years of dependable operation.
These units have been tested by Underwriters' Laboratories and
will be shipped with UL and CUL labels.
OUTDOOR UNIT
Every outdoor unit includes a heavy-duty compressor with a
crankcase heater, line break overload protection, a suction line
accumulator with a fusible plug, a 4-way reversing valve with a
24-volt solenoid, outdoor fan motor(s) with inherent protection,
and a copper tube/aluminum fin coil that is positioned vertically for
better drainage of the water that will condense on it during the
heating cycle.
They also include a filter-drier, an expansion valve and a distribu-
tor that are only used during the heating cycle plus a check valve
to provide the proper flow of refrigerant through the unit during
both the cooling and heating cycles.
To eliminate the costly cabinet deterioration problems usually
associated with outdoor equipment, all sheet metal parts are con-
structed of commercial grade (G90) galvanized steel. After fabri-
cation, each part is thoroughly cleaned to remove any grease or
dirt from its surfaces. The parts that will be exposed to the
weather are then coated with a powder paint to assure a quality
finish for many years. This coating system has passed the 750
hour, salt spray test per ASTM Standard B117. To assist in ser-
vicing, the high and low pressure service connections are exterior
to the cabinet, allowing simple access.
The fan guards are vinyl-coated to provide additional rust protec-
tion. An optional decorative coil guard is available to protect the
coil on the outdoor unit.
INDOOR UNIT
Every indoor unit includes a well-insulated cabinet, a copper tube/
aluminum fin coil, 1" throwaway filters, a centrifugal blower, a
blower motor, adjustable drive components, a blower motor con-
tactor and a small holding charge of Refrigerant-22.
They also include a filter-drier, an expansion valve and a distribu-
tor that are only used during the cooling cycle; also, a check valve
to provide the proper flow of refrigerant through the coil during
both the cooling and heating cycles.
The units are shipped in the vertical position ready for field instal-
lation. For horizontal installation, interchange the solid bottom
panel and the return air duct flange on the front of the unit.
http://www.rezine.net
Page 43
Summary of Contents for HA090
Page 42: ...http www rezine net Page 42 ...
Page 59: ...http www rezine net Page 59 ...
Page 60: ...http www rezine net Page 60 ...
Page 63: ...http www rezine net Page 63 ...
Page 70: ...http www rezine net Page 70 ...
Page 97: ...http www rezine net Page 97 ...
Page 98: ...http www rezine net Page 98 ...
Page 100: ...http www rezine net Page 100 ...
Page 103: ...http www rezine net Page 103 ...
Page 110: ...http www rezine net Page 110 ...
Page 158: ...http www rezine net Page 158 ...
Page 166: ...http www rezine net Page 166 ...
Page 167: ...http www rezine net Page 167 ...
Page 169: ...http www rezine net Page 169 ...
Page 172: ...http www rezine net Page 172 ...
Page 179: ...http www rezine net Page 179 ...
Page 182: ...http www rezine net Page 182 ...
Page 206: ...http www rezine net Page 206 ...
Page 207: ...http www rezine net Page 207 ...
Page 209: ...http www rezine net Page 209 ...
Page 212: ...http www rezine net Page 212 ...
Page 219: ...http www rezine net Page 219 ...
Page 222: ...http www rezine net Page 222 ...