For additional connection diagrams for all UPG equipment refer to “Line Voltage System Wiring” document available on-line at www.upgnet.com in
the Product Catalog Section.
FIGURE 5:
Thermostat Chart – Two Stage AC - Variable Speed Modulating Furnace
AC 26A
Two
Stage Air Conditioner – Variable Speed Modulating Furnace
C
24 – Volt Common
Y1
First Stage Compressor
Y2
Second Stage
Compressor
G
Fan
*PP32U70124
THERMOSTAT
AUX
Auxiliary Heat
R
24 – Volt Hot
(Heat XFMR)
R
24 – Volt Hot
(Cool XFMR)
C
24 – Volt Common
Y1
First Stage Compressor
Y2
Second Stage
Compressor
G
Fan
*DN22U00124
THERMOSTAT
W2
Second Stage Heat
R
24 – Volt Hot
(Heat XFMR)
R
24 – Volt Hot
(Cool XFMR)
E/W1
Emergency Heat
E/W1
First Stage Heat
TWO STAGE
AIR
CONDITIONER
C
24 – Volt Common
R
24 – Volt Hot
Y1
First Stage Compressor
Y2
Second Stage
Compressor
C
24 – Volt Common
R
24 – Volt Hot
Y1
Single Stage Compressor
VARIABLE SPEED
MODULATING
FURNACE CONTROL
G
Fan
VARIABLE SPEED
MODULATING
FURNACE
Y/Y2
Second or Full
Stage Compressor
HUM
Dehumidification-
Open on Humidity Rise
W
Modulating Heat
Part Numbers:
SAP = Legacy
171334 = 031-09153
1
1
Move HUMIDISTAT
jumper to “YES”
if humidistat is to be used.
FL9C
FC9C
PC9
ID MODELS
External Humidistat
(Optional)
Open on Humidity Rise
24VAC Humidifier
(Optional)
External Humidistat
(Optional)
Open on Humidity Rise
2
2
Connection of the “C”
terminal, 24-Volt common
is optional when used with
batteries
Thermostat Installer Setup
0170-System Type-must
be set to 8-2 Heat/2 Cool
Multistage Conventional
Connection of the “C”
terminal, 24-volt common
is optional when used with
batteries
Thermostat Installer Setup
1-System Type-must
be set to 6-2 Heat/2 Cool
Multistage Conventional
Thermostat Installer Setup
15-Compressor Protection
-must be set to 5
Part Number:
S1-2HU16700124
2