145
YORK INTERNATIONAL
FORM 100.50-NOM1 (604)
8
LD09839
7R-1
14OL
2T
115V - 24V CONTROL
TRANSFORMER
75 VA, CLASS 2
5FU
1T
115V - 24V CONTROL
TRANSFORMER
100 VA, CLASS 2
14M
11R-1
6FU
1M-4
2M-4
3M-4
4M-4
5M-4
6M-4
CRANKCASE HEATER
COMPRESSOR 1A
CRANKCASE HEATER
COMPRESSOR 1B
CRANKCASE HEATER
COMPRESSOR 2A
CRANKCASE HEATER
COMPRESSOR 2B
CRANKCASE HEATER
COMPRESSOR 3A
CRANKCASE HEATER
COMPRESSOR 3B
COMPRESSOR 1A
113, 114, 115
COMPRESSOR 1B
118, 119, 120
COMPRESSOR 2A
122, 123, 124
COMPRESSOR 2B
127, 128, 129
COMPRESSOR 3A
131, 132, 133
COMPRESSOR 3B
136, 137, 138
CONDENSER FAN 1A
141, 142, 143
CONDENSER FAN 1B
144, 145, 146
CONDENSER FAN 2A
148, 149, 150
CONDENSER FAN 2B
151, 152, 153
CONDENSER FAN 3A
155, 156, 157
CONDENSER FAN 3B
158, 159, 160
SYS 3 LIQUID LINE
SOLENOID VALVE
EXHAUST FAN
133, 134, 135
SYS 2 LIQUID LINE
SOLENOID VALVE
SYS 1 LIQUID LINE
SOLENOID VALVE
PUMP DOWN
OPT. HOT GAS
SOLENOID VALVE
TS
206
205
204
203
202
201
200
207
208
209
210
211
212
213
214
215
216
217
218
219
220
224
225
228
229
230
231
232
233
234
235
236
240
241
242
243
244
245
246
247
248
249
250
251
252
X1
2
1
2
2
2
2
2
2
2
2
2
13
4
5
PRI
SEC
NOTE: THIS CIRCUIT IS OMITTED IF THE UNIT IS EQUIPPED WITH A
EXHAUST FAN VFD.
7
PRI
SEC
PRI
SEC
3T
J41
J41
J42
J42
J43
J43
J44
J44
J45
J45
J46
J46
100
COM
200
2COM
ELEMENTARY DIAGRAM - YPAL MOD-C
CLASS 1 CONTROL
70-105 TON
035-13473-102
REV. A
REFER TO LINE #
124, 125, 126, 127
38
37
28
27
18
17
REFER TO
LINE # 300-306
TS
7R
2
2CB
20
19
COMPRESSOR MOTOR PROTECTORS
SYSTEM #1
REFER TO LINE #S 266-273
4CB
29
30
8R
TS
2
6CB
39
40
TS
9R
2
253
254
255
256
NOTE: THIS CIRCUIT IS USED ON UNITS EQUIPPED WITH AN
ON/OFF SUPPLY FAN. (CV UNITS)
10R-1
3
13OL
5
TS
13M
SUPPLY FAN
120, 121, 122
139, 140, 141
2
10R-1
OPTIONAL SUPPLY FAN VFD
BYPASS KIT
REFER TO LINES
290 - 293
2
3
J51
2
SFR
OPTIONAL EXHAUST FAN VFD
BYPASS KIT
REFER TO LINES
294-297
EFR
11R-1
2
J53
3
2
J53
J51
NOTE: THIS CIRCUIT IS USED IF UNIT IS EQUIPPED WITH A VARIABLE FREQUENCY DRIVE ON
THE SUPPLY FAN (VAV AND VAV-FLEXSYS UNITS). THE SUPPLY FAN VFD BYPASS KIT IS
OPTIONAL.
NOTE: THIS CIRCUIT IS USED ON UNITS EQUIPPED WITH
ON/OFF POWERED EXHAUST.
NOTE: THIS CIRCUIT AND CAP J53 IS USED IF UNIT IS EQUIPPED WITH A POWERED EXHAUST FAN
DRIVEN BY A VARIABLE FREQUENCY DRIVE. THE EXHAUST FAN VFD BYPASS KIT IS OPTIONAL.
SUPPLY FAN WIRING
REFER TO LINE #S 260-262
OPTIONAL EXHAUST FAN WIRING
REFER TO LINE #S 263-265
2
2
1HPCO
3
M
2
CM1
CM2
P41
COMPRESSOR MOTOR PROTECTOR WIRING FOR
SYSTEM #1. CM1 AND CM2 ARE LOCATED IN
COMPRESSORS 1A AND 1B, RESPECTIVELY. 1HPCO IS
LOCATED ON DISCHARGE LINE BEHIND COMPRESSOR
1A.
17M
16OL
XOO
OOX
BYPASS
VFD
VFD
BYPASS
SW2-1
3
2
J50
CONNECTED TO J51 IN THE
CONTROL BOX
REFER TO LINE #S
261 & 262
OFF
15M
16M
SW2-2
R
2
8
10
SFR
2
SW3-2
SW3-1
10
18M
20M
19M
19OL
8
VFD
BYPASS
XOO
BYPASS
OOX
VFD
OFF
3
CONNECTED TO J53 IN THE
CONTROL BOX
REFER TO LINE #S
264 & 265
EFR
2
2
R
J52
2
296
295
294
262
268
269
267
266
265
264
263
261
260
297
292
293
291
290
COMPRESSOR MOTOR PROTECTORS
SYSTEM #2
REFER TO LINE #S 274-281
COMPRESSOR MOTOR PROTECTORS
SYSTEM #1
REFER TO LINE #S 282-289
OPTIONAL SUPPLY FAN VFD BYPASS KIT. LOCATED IN THE FAN
SECTION UNDER THE SUPPLY FAN VFD.
OPTIONAL EXHAUST FAN VFD BYPASS KIT. LOCATED IN THE
FAN SECTION UNDER THE EXHAUST FAN VFD.
4
P42
3
4
19
2
M
M2
JMP
JMP
M
M2
J41
J42
272
273
271
270
2
2
2
COMPRESSOR MOTOR PROTECTOR WIRING FOR
SYSTEM #2. CM3 AND CM4 ARE LOCATED IN
COMPRESSORS 2A AND 2B, RESPECTIVELY. 2HPCO IS
LOCATED ON DISCHARGE LINE BEHIND COMPRESSOR
2A.
29
M2
282
4
J44
J43
281
280
279
278
276
274
275
JMP
JMP
M
M2
M
P44
3
4
3
P43
CM4
CM3
2HPCO
COMPRESSOR MOTOR PROTECTOR WIRING FOR
SYSTEM #3. CM5 AND CM6 ARE LOCATED IN
COMPRESSORS 3A AND 3B, RESPECTIVELY. 3HPCO IS
LOCATED ON DISCHARGE LINE BEHIND COMPRESSOR
3A.
39
M2
4
J46
J45
289
288
287
286
285
283
284
JMP
JMP
M
M2
M
P46
3
4
3
P45
CM6
CM5
3HPCO
277
5CB
3CB
1CB
19B
29B
39B
NOTE: THIS CIRCUIT IS OMITTED IF THE UNIT IS EQUIPPED WITH A
SUPPLY FAN VFD.
5
5
5
5
5
M2
M2 M
M2 M
M2 M
M2 M
M2 M
T2 T1
T2 T1
2
2
2
2
2
2
T2 T1
2
2
T2 T1
2
2
2
T2 T1
2
2
T2 T1
Q
13
HGSV
J40
GND
1LLSV
J56
15
GND
TS
8M
7M
TS
3
J40
J40
3
2
2
J56
J56
2
2
2
2
TS
2M
TS
1M
2
2
2LLSV
J56
4
25
10M
TS
TS
23
22
9M
4M
TS
TS
3M
J56
5
2
2
2
2
2
GND
J56
3LLSV
J56
7
35
GND
12M
TS
33
32
6M
11M
TS
TS
TS
5M
J56
J56
8
2
2
2
2
2
115 VAC
21
8R-1
31
9R-1
2
Q2
2
Q3
2
Q4
2
SR1
SR-XM1
Q4
2
Q3
2
Q2
2
Q
2
Q4
2
Q3
2
Q2
2
Q
2
SR-XM2
14
12
13
24
34
23
33
4LLSV
J39
GND
OPT. SYS 1 LIQUID
LINE SOLENOID VALVE
(FLEXSYS UNITS ONLY)
J39
J39
3
2
2
2M-5
1M-5
3M-5
4M-5
5LLSV
J39
GND
OPT. SYS 2 LIQUID
LINE SOLENOID VALVE
(FLEXSYS UNITS ONLY)
J39
J39 2
4
5
5M-5
6M-5
6LLSV
J39
GND
OPT. SYS 3 LIQUID
LINE SOLENOID VALVE
(FLEXSYS UNITS ONLY)
J39
J39 2
7
8
226
222
223
221
227
237
239
238
16
16B
26
26B
36
36B
COMPRESSOR SYSTEM
PROTECTION CIRCUIT
SYSTEM #1
COMPRESSOR SYSTEM
PROTECTION CIRCUIT
SYSTEM #2
COMPRESSOR SYSTEM
PROTECTION CIRCUIT
SYSTEM #3