5-4
SM-16005-rev.2
EXTERNAL INPUT/OUTPUT AND FUNCTION SETTING
7. Select “Yes” and press “OK”.
The Test Run menu is displayed after the setting is
confirmed.
If “No” is selected, the screen returns to "4".
OK
Function Selection:01-03
b1
00
01
23
b2
00
b3
00
b4
00
b5
00
Item
Setting
/
Adj.
Entr
Rtrn
Sel.
Back
Function Selection:01-03
01
23
b1
00
b2
00
b3
01
b4
00
b5
00
Item
Setting
/
Adj.
Entr
Rtrn
Sel.
Back
OK
Back
OK
Input/Output:01-03
Input 1
00
CN3 1-2
Input 2
00
CN3 2-3
Output1
00
CN7 1-2
Output2
00
CN7 1-3
Output3
00
CN8 1-2
Item
Setting
Connector
Adj.
Entr
Rtrn
Sel.
Back
OK
Input/Output:01-03
Input 1
00
CN3 1-2
Input 2
00
CN3 2-3
Output1
01
CN7 1-2
Output2
00
CN7 1-3
Output3
00
CN8 1-2
Item
Setting
Connector
Adj.
Entr
Rtrn
Sel.
Back
1. Press and hold “Menu” and “Back/Help” simultaneously
for at least three seconds during the normal mode (when
unit is not operated). The Test Run menu is displayed.
2. Select “Function Selection” or “Input/Output” from the
Test Run menu and press “OK”.
OK
Test Run Menu
Elevating Grille Setting
Input/Output
Thermistor Selection
Function Selection
01
/
03
Test Run
Entr
Rtrn
Sel.
Back
OK
Function Selection
01-01
All
01-02
01-03
01-04
Entr
Rtrn
Sel.
Back
3. Select the indoor unit by pressing “
” and touch
“OK”.
(This screen is NOT displayed when the number of an
indoor unit connected with the controller is
"1". In this case, "4" is displayed.)
Function Selection
4. Press “
” and select the item.
5. Press “
” and change the setting.
Input/Output Setting
4. Press “
” and select the item.
5. Press “
” and change the setting.
OK
Confirm function
selection setting?
Function Selection:01-03
Yes
No
Sel.
Entr
Rtrn
Back
6. Press “OK” so that the confirmation screen is displayed.
8. Press “Back/Help” on the Test Run menu to return to the
normal mode.
(Figure for Function Selection)
To set other units, press “Back/Help” at "4" and "5" so that the screen returns to "3".
(If the number of an indoor unit connected with the controller is "1", the screen returns to "1".)
● Function Selection and Input/Output Setting
Summary of Contents for CIDM030B21E
Page 2: ......
Page 10: ...viii SM 16005 rev 2...
Page 14: ......
Page 15: ...SM 16005 rev 2 1 1 INSTALLATION 1 Installation...
Page 19: ...SM 16005 rev 2 2 1 OPERATION 2 Operation...
Page 22: ......
Page 23: ...SM 16005 rev 2 3 1 TROUBLESHOOTING 3 Troubleshooting...
Page 70: ......
Page 71: ...SM 16005 rev 2 4 1 MAINTENANCE 4 Maintenance...
Page 130: ......
Page 131: ...SM 16005 rev 2 6 1 FIELD WORK INSTRUCTIONS 6 Field Work Instructions...
Page 140: ...6 10 SM 16005 rev 2 FIELD WORK INSTRUCTIONS 6 8 Mollier Chart for R410A f t 3 l b...
Page 141: ...SERVICE PARTS LIST SM 16005 rev 2 7 1 7 Service Parts List...
Page 143: ......
Page 144: ...2016 Johnson Controls Inc SM 16005 rev 2 Code No LIT 12012293 Revised February 2019...