background image

 

 

 

 

 

 

 

 

 

 

VERTICAL WINDOW AIR 

CONDITIONER 

(1.75KW, COOLING ONLY) 

KAVWAC2KYA 

Summary of Contents for KAVWAC2KYA

Page 1: ...VERTICAL WINDOW AIR CONDITIONER 1 75KW COOLING ONLY KAVWAC2KYA ...

Page 2: ......

Page 3: ...all be observed o The mechanical connections shall be accessible for maintenance purposes o For appliances containing flammable refrigerants the minimum floor area of the room shall be mentioned in the form of a table or a single figure without reference to a formula Keep any required ventilation openings clear of obstruction Ensure ducts connected to the appliance does not contain a potential ign...

Page 4: ...le for their safety Supervise children to ensure they do not play with this appliance Install the appliance correctly to ensure it is at a minimum allowable distance from the adjacent structures See the Installation section of this user guide Follow the correct wiring connection type when operating or repairing Do not use the appliance in an explosion hazardous room Do not use the appliance in a c...

Page 5: ... device and unplug the power cord from the power outlet If you notice damage to the power plug or power cord cease the use of the appliance and contact Kogan com When placing the appliance pay attention to the minimum distance from walls and other objects For storage and operating conditions see the Cleaning and Care section of this user guide Ensure that air inlets and outlets are not blocked Mak...

Page 6: ... 2 Vertical Blade Auto Swing 3 Level Blade Manually Swing 4 Filter 5 Display Panel 6 Power Line 7 Indoor Water Hole 8 Back Panel 9 Outdoor Air Inlet 10 Outdoor Water Hole 11 Outdoor Air Outlet 12 Standard Frame 13 Chassis OVERVIEW ...

Page 7: ...Air Conditioner Window Frame Protect Plate Seal Sponge Sliding Screw Seal Rubber Inside Frame Dead Plate Fix Screw Standard Frame Sliding Plate Unit Fixed Screw Unit Locker Down Sliding Plate ...

Page 8: ...he unit on a horizontal surface to avoid water leakage Air Conditioner Window Frame Installation Requirements The height of the window should be higher than 85cm The window should have a groove If there is no groove e g wood window contact professional people to install The window height should be shorter than the max height of the frame to avoid the appliance from falling INSTALLATION ...

Page 9: ...ments are required o Tape o Cross screwdriver o Scissor Power supply details o Connect to a power supply directly and do not use an extension cord o Ensure the plug is connected Sketch the map of the frame for installation ...

Page 10: ...r window frame Sliding Locked Screw Standard Frame Inside Frame Unit Location Fixed Screw Protect Plate First Groove Inside Outside Note Cover the window completely with the Standard Frame Note To install the air conditioner wait for two hours after delivery to keep the refrigerant gas stable ...

Page 11: ...ndow III 5 Use two screws to lock the Inside Frame Position the protector between the top and bottom and tighten the screws IV 6 Use a suitable sponge to seal the remaining gaps V Step 3 Install the air conditioner 1 Unscrew the standard frame 2 There are two holes with a locker on the backside of the air conditioner push one time to lock Unit Lock Screw Unit Locker Frame inside the rubber Back Si...

Page 12: ...onditioner Step 4 Disassemble the air conditioner 1 Follow the air condition installation steps in the reverse order to disassemble the air conditioner 2 Push the Unit Locker to left and hold the air conditioner to avoid dropping Unit Fixed Screw Note Be careful when disassembling the air condition Do not drop the air conditioner Note Ensure the air condition is installed securely ...

Page 13: ...nel 4 TIMER Press this button to turn off or turn on the timer 5 FAN Press this button to change the fan speed high middle or low 6 UP DOWN Press to increase or decrease the temperature and timer settings 7 SWING Press this button to turn on or off the swing function 8 SLEEP Press this button to put the air conditioner to sleep mode 9 MODE Press this button to switch between auto cooling fan and d...

Page 14: ...ing indicator lights up 2 Press the UP and DOWN keys to set the appropriate temperature The setting range is 16 30 C Each time you press the up or down button the temperature will rise or fall by 1 C 3 Press the FAN button to select the appropriate fan speed and you can cycle through low mid and high wind 4 Press the SWING button to turn the swing function on or off Dehumidify mode 1 Press the MOD...

Page 15: ... corresponding indicator lights up In this mode it operates according to the cooling function 2 The default setting temperature is 26 C The setting range is 16 30C and the temperature can be adjusted within this range 3 The fan speed is set to low and is not adjustable 4 Press the swing key to turn off and turn on the swing function 5 After entering sleep mode the indicator light turns dark and th...

Page 16: ... shall be available to hand Have a dry powder or CO2 fire extinguisher adjacent to the charging area 6 No ignition sources No person carrying out work in relation to a refrigerating system which involves exposing any pipe work shall use any sources of ignition in such a manner that it may lead to the risk of fire or explosion All possible ignition sources including cigarette smoking should be kept...

Page 17: ...ration an adequate temporary solution shall be used This shall be reported to the owner of the equipment so all parties are advised Initial safety checks shall include That capacitor is discharged this shall be done safely to avoid the possibility of sparking That no live electrical components and wiring are exposed while charging recovering or purging the system That there is continuity of earth ...

Page 18: ...urpose conventional procedures shall be used However for flammable refrigerants best practice must be followed since flammability is a consideration The following procedure shall be adhered to Remove refrigerant Purge the circuit with inert gas Evacuate Purge with inert gas Open the circuit by cutting or brazing The refrigerant charge shall be recovered into the correct recovery cylinders For appl...

Page 19: ...en in case analysis is required before re use of recovered refrigerant Electrical power must be available before the task is commenced a Become familiar with the equipment and its operation b Isolate the system electrically c Before attempting the procedure ensure that Mechanical handling equipment is available if required for handling refrigerant cylinders All personal protective equipment is ava...

Page 20: ... a set of instructions concerning the equipment that is at hand and shall be suitable for the recovery of all appropriate refrigerants including when applicable flammable refrigerants Also a set of calibrated weighing scales shall be available and in good working order Hoses shall be complete with leak free disconnect couplings and in good condition Before using the recovery machine check that it ...

Page 21: ...conditioner s performance Clean the filter every two weeks 1 Remove the standard screws fixed on the grille and the front panel 2 Pull down the grille to remove it Then remove the filter from the front panel 3 Put the filter into warm water about 40 C or 104 F which has neutral detergent rinse it and dry it in a cool place CLEANING CARE Pull Up to Close Grille Screw Hole Filter Pull Down to Open N...

Page 22: ...ode to the low air condition Keep this state for a long time until the catheter dries This operation will dry the inside of the body and prevent mould 3 Turn off the machine and unplug the power cord Wrap the power cord and install a water plug 4 Remove the machine from the window remove the mounting bracket and keep it in a good condition 5 Put the air conditioner in a plastic bag and put it in a...

Page 23: ...itioner makes loud noise The air conditioner is not installed correctly Check the frame and air conditioner to ensure proper and correct installation Compressor is not working Overheat protection is on Wait for 3 minutes until the temperature drops and then turn it on Air conditioner remote does not work The remote is used at from a long distance Keep the remote control close to the air conditione...

Page 24: ...tion We hope that this user guide has given you the assistance needed for a simple set up For the most up to date guide for your product as well as any additional assistance you may require head online to help kogan com ...

Reviews: