SM-16005-rev.2
3-29
TROUBLESHOOTING
l
The RUN indicator (red) flashes.
l
The indoor unit number (refrigerant cycle number - address number), the alarm code, the model code*
1)
,
the model name*
1)
and the number of connected indoor units are displayed on the LCD. The indoor unit
number and the alarm code are displayed on the 7-segment display of the outdoor unit PCB.
*1) Except for some models.
H
This alarm code is displayed when the indoor fan motor rotates at less than 70rpm for five seconds
three times in 30 minutes during the operation.
Failure of I.U. PCB2
Failure of Fan Motor
Failure of I.U. PCB2
(*1)
Abnormal voltage is supplied
for fan motor.
Is LED1 on
I.U. PCB2 OFF?
(*1)
Check connectors PCN201
and CN201 on I.U. PCB2.
No
No
Yes
Does fan motor run?
Replace I.U. PCB2.
Replace Fan Motor.
Replace I.U. PCB2.
Replace Fan Motor
Yes
Yes
Occurrence of
Alarm Code “19”
(Normal Voltage: DC 280V)
Failure of Fan Motor
No
Check that 208/230V
is applied between
L1 and L2 of TB1.
NOTE:
Turn OFF the power supply completely before
connector checking.
Otherwise, it may cause a DC fan motor failure.
(Built-in PCB for the DC fan motor may be damaged.)
Dose fan motor
meet decision basis
at “Checking for
Fan Motor”?
● Perform the following
check after setting the airflow
volume to “HIGH”.
● A high voltage is applied
to electrical parts.
Perform the check carefully
to prevent an electric shock.
Alarm
Code
Activation of Protection Device for Indoor Fan Motor
(for Ducted (Medium Static) with EconoFresh Kit)
Summary of Contents for CIDM030B21E
Page 2: ......
Page 10: ...viii SM 16005 rev 2...
Page 14: ......
Page 15: ...SM 16005 rev 2 1 1 INSTALLATION 1 Installation...
Page 19: ...SM 16005 rev 2 2 1 OPERATION 2 Operation...
Page 22: ......
Page 23: ...SM 16005 rev 2 3 1 TROUBLESHOOTING 3 Troubleshooting...
Page 70: ......
Page 71: ...SM 16005 rev 2 4 1 MAINTENANCE 4 Maintenance...
Page 130: ......
Page 131: ...SM 16005 rev 2 6 1 FIELD WORK INSTRUCTIONS 6 Field Work Instructions...
Page 140: ...6 10 SM 16005 rev 2 FIELD WORK INSTRUCTIONS 6 8 Mollier Chart for R410A f t 3 l b...
Page 141: ...SERVICE PARTS LIST SM 16005 rev 2 7 1 7 Service Parts List...
Page 143: ......
Page 144: ...2016 Johnson Controls Inc SM 16005 rev 2 Code No LIT 12012293 Revised February 2019...