ECONOMIZER DOWN DISCHARGE / SUPPLY KIT - Modu-
lating integrated economizer provides simultaneous opera-
tion between the mechanical cooling and economizer
operation. Independent blade design insures proper control
and less than 1% leak rate. Includes hood and mesh bird
screen filter integrated into the hood, dry bulb sensor and re-
lief damper. Separate field accessories of single enthalpy and
dual enthalpy are also available.

SINGLE ENTHALPY SENSOR - Sensor replaces dry bulb
sensor standard in economizer kit. Provides improved econo-
mizer operation by sensing the dry bulb temperature from out-
doors plus the enthalpy content of the outdoor air.

DUAL ENTHALPY SENSOR - Additional sensor to single en-
thalpy sensor. Sensor senses both the return air temperature
dry bulb and humidity in conjunction with the single enthalpy
to determine the most economical mix. Single Enthalpy sen-
sor also required.

UPGRADE PRESSURE PACKAGE - Contains screw in type
High pressure, Low Pressure/Loss of Charge switch, freeze
protection switch and lockout relay. Switches are placed onto
existing schrader ports located in the unit by furnished adapt-
ers. When abnormal conditions are sensed through the pres-
sure switches, the unit will lock out preventing any further
operation until reset or problem is corrected. Package agency
approved.

HAIL GUARD KIT - Kit contains protected grilles made of ex-
panded aluminum grilles with full perimeter

1

1

2

inch frame.

Sloped hoods are also included to assure maximum protec-
tion.

FILTER / FRAME KIT (Single Phase only) - Kit contains the
necessary hardware to field install return air filters into the
base unit. Pre-cut filter racks and appropriate cleanable stan-
dard size filters are shipped in one kit. (1" filter is supplied)
This kit is available for single phase horizontal or vertical duct
application only. Standard in all 3 Phase models.

MOTORIZED FRESH AIR DAMPER - Designed for duct
mounted side supply/return and unit mounted down sup-
ply/return applications. Damper capable of providing 0% thru
50% of outdoor air (field supplied). Closes on power loss, in-
cludes hood and screen assembly.

RECTANGLE TO ROUND ADAPTERS - Kit includes one sup-
ply and one return air rectangle to round duct adapter. Adapters
are preformed and designed to fit over current duct openings on
the base unit. Transition is from 15" square to 14" round.

ROOF CURBS - NRCA approved curbs provide proper fit to
base unit for rooftop installations. Curbs are designed to be
assembled through hinge pins in each corner. Kit also pro-
vides seal strip to assure a water tight seal. 8 and 14 inch high
roof curbs are available.

MANUAL OUTDOOR DAMPER - Provides 0% thru 50% out-
door air capability (field adjustable). Designed for duct
mounted side supply/return applications. Includes hood and
screen assembly.

WALL THERMOSTAT - The units are designed to operate
with 24-volt electronic and electro-mechanical thermostats.
All units can operate with single stage heat / single stage cool
thermostats - with or without the economizer.

TRANSFORMER KIT (Single Phase only) - Kit provides
necessary hardware to provide single phase models from fac-
tory furnished 40 VA transformer capability to 75 VA trans-
former capability.

ELECTRIC HEATERS - Each heater package provides easy
installation of electric heat strips. Slide in design with plug in
harness and agency approved. Heaters are available from
5.0 KW sizes and are designed for single and dual point con-
nections.

036-21311-003-A-0104

Unitary Products Group

3

FIELD-INSTALLED ACCESSORIES

TABLE OF CONTENTS

Description .........................................................................1
Features and Benefits .................................................1 & 2
Field-installed Accessories ................................................3
Ratings...............................................................................4
Physical Data .....................................................................4
Cooling Capacities - BHA018 ............................................5
Cooling Capacities - BHA024 ............................................6
Cooling Capacities - BHA030 ............................................7
Cooling Capacities - BHA036 ............................................8
Cooling Capacities - BHA042 ............................................9
Cooling Capacities - BHA048 ..........................................10
Cooling Capacities - BHA060...........................................11
Heating Capacities - BHA018 & 024 ................................12
Heating Capacities - BHA030 & 036 ................................13
Heating Capacities - BHA042 & 048 ................................14
Heating Capacities - BHA060 ..........................................15
Application Data ...............................................................15

Additional Static Pressure Resistance .............................15
Side and Bottom Supply Air Blower Performance ...........16
Field Wiring Diagram .......................................................17
Electrical Data (basic unit) ...............................................17
Electrical Data (cooling / electric heat).............................18
Unit Dimensions ...............................................................20
Center of Gravity ..............................................................21
Clearances.......................................................................21
Typical Applications .........................................................22
Roof Curb Dimensions .....................................................23
Roof Curb Application ......................................................23
Typical Wiring Diagram (208/230-1-60) ...........................24
Typical Wiring Diagram (208/230-3-60) ...........................25
Typical Wiring Diagram (460-3-60 & 575-3-60) ...............26
Typical Wiring Diagram Notes..........................................27
Typical Wiring Diagram Legend .......................................27
Mechanical Specification .........................................28 & 29

Summary of Contents for Champion Series

Page 1: ...currents air velocity and temperature and unit vibration are monitored and recorded by the system to insure unit performance Equal size side supply and return duct connections allows easy hook up of d...

Page 2: ...o aids in sound alterations with it s Super Structure design This design strategically places embossments in the pan for optimum strength and rigidity FAN SYSTEM All models operate over a wide range o...

Page 3: ...sup ply and one return air rectangle to round duct adapter Adapters are preformed and designed to fit over current duct openings on the base unit Transition is from 15 square to 14 round ROOF CURBS NR...

Page 4: ...annual usage period for cooling divided by the total electric power input in watt hours during the same period COP Coefficient of Performance the total heating capacity provided by the refrigeration...

Page 5: ...2 23 2 16 2 11 2 12 Sensible Capacity MBH 1 Entering Dry Bulb F 86 10 9 13 4 13 9 13 8 12 3 14 8 14 4 14 3 13 6 16 3 14 9 14 8 14 9 17 1 15 3 15 2 16 2 17 9 15 7 15 6 83 9 6 12 1 13 6 13 5 10 7 13 5...

Page 6: ...4 Sensible Capacity MBH 1 Entering Dry Bulb F 86 13 9 17 3 17 9 17 9 15 5 18 8 18 5 18 4 17 1 20 3 19 1 19 0 18 6 21 0 19 4 19 4 20 1 21 6 19 8 19 8 83 12 2 15 6 17 6 17 6 13 5 17 3 18 4 18 3 14 8 19...

Page 7: ...Capacity MBH 1 Entering Dry Bulb F 86 17 6 21 9 22 5 22 6 19 5 23 6 23 0 23 0 21 5 25 3 23 5 23 5 23 5 26 1 23 9 24 0 25 5 26 9 24 4 24 4 83 15 5 19 8 22 2 22 3 17 0 21 7 22 8 22 9 18 5 23 5 23 5 23 5...

Page 8: ...Entering Dry Bulb F 86 21 0 25 8 25 1 23 7 23 9 28 4 27 0 25 5 26 9 31 1 28 8 27 2 29 5 32 9 30 0 28 3 32 1 34 6 31 2 29 5 83 18 5 23 2 25 1 23 7 20 9 26 2 27 0 25 5 23 4 29 3 28 8 27 2 25 5 31 3 30...

Page 9: ...H 1 Entering Dry Bulb F 86 23 4 29 0 27 9 25 3 26 5 31 9 30 1 27 3 29 6 34 8 32 3 29 3 32 0 35 8 32 7 29 7 34 4 36 9 33 1 30 1 83 20 4 26 0 27 9 25 3 23 0 29 2 30 1 27 3 25 5 32 3 32 3 29 3 27 3 33 9...

Page 10: ...lb F 86 28 3 35 7 38 8 36 8 31 6 39 3 40 0 38 0 34 9 43 0 41 3 39 2 38 2 44 7 42 1 40 0 41 4 46 5 43 0 40 9 83 24 8 32 3 36 9 36 0 27 5 35 7 39 1 37 6 30 2 39 1 41 3 39 2 32 8 42 0 42 1 40 0 35 4 44 8...

Page 11: ...5 44 3 46 6 45 4 38 4 48 2 47 8 46 5 42 3 52 2 48 9 47 6 43 7 53 1 49 6 48 3 45 1 54 1 50 3 48 9 83 30 3 40 0 45 7 44 6 33 4 44 1 47 3 46 1 36 5 48 1 48 9 47 6 37 5 49 3 49 6 48 3 38 5 50 6 50 3 48 9...

Page 12: ...2 543 15 457 19 060 23 517 29 028 KW 1 428 1 581 1 733 1 886 2 038 2 190 2 343 2 495 1 These capacities are net capacities the indoor motor heat has been added These power inputs are total power input...

Page 13: ...2 25 624 30 154 35 507 41 834 KW 2 566 2 694 2 822 2 950 3 078 3 206 3 335 3 463 1 These capacities are net capacities the indoor motor heat has been added These power inputs are total power inputs th...

Page 14: ...ities the indoor motor heat has been added These power inputs are total power inputs the indoor motor watts have been added HEATING CAPACITIES 4 TON BHA048 CFM RETURN AIR CAP1 OUTDOOR AIR TEMPERATURE...

Page 15: ...N DATA MODEL BHA 018 024 030 036 042 048 060 MINIMUM AIR FLOW CFM COOLING 450 600 750 900 1 050 1 200 1 500 HEATING 450 600 750 900 1 050 1 200 1 500 MAXIMUM AIR FLOW CFM COOLING 750 1 000 1 250 1 500...

Page 16: ...788 691 1739 1652 1528 940 752 677 NOTE Above data includes allowances for a dry indoor coil and no filters For additional pressure drops refer to the Additional Static Pressure Resistance table MODEL...

Page 17: ...253 11 2 60 0 1 1 2 6 17 7 25 25 96 40 030 208 230 1 60 187 253 12 0 73 0 1 1 2 6 18 7 25 25 96 40 036 208 230 1 60 187 253 17 3 94 0 1 1 3 5 26 2 35 35 96 40 042 208 230 1 60 187 253 20 5 120 0 1 1 3...

Page 18: ...88 1 103 7 114 1 126 3 140 2 148 8 166 2 90 100 110 125 150 150 150 175 90 100 110 125 150 150 150 175 060 208 230 1 60 28 9 165 0 1 5 7 0 2NH04501006 2NH04501506 2NH04502006 2NH04502506 2 2 2 2 7 5...

Page 19: ...25 0 9 6 14 4 19 2 24 1 21 3 27 3 33 3 39 3 25 30 35 40 25 30 35 40 060 575 3 60 6 4 50 0 0 6 2 8 2NH04501058 2NH04501558 2NP04502058 2NP04502558 1 1 2 2 10 0 15 0 20 0 25 0 9 6 14 4 19 2 24 1 23 4 2...

Page 20: ...LTAGE CONN 7 8 DIA KNOCKOUT HIGH VOLTAGE CONN 131 32 DIA KNOCKOUT FRONT ELECTRICAL FILTER SERVICE ACCESS COMPARTMENT PANEL OVERALL OVERALL 4 1 2 11 2 2 1 2 All dimensions are in inches They are subjec...

Page 21: ...S THEREAFTER FOR ALL OTHER HEATERS ZERO INCH CLEARANCE ALL SIDES FOR ENTIRE LENGTH OF DUCT FLEXIBLE DUCT COLLAR NOTE FOR UNITS APPLIED WITH A ROOF CURB THE MINIMUM CLEARANCE MAY BE REDUCED FROM 1 INCH...

Page 22: ...FIELD SUPPLIED DISCONNECT SWITCH LOCATED TO REAR OF UNIT CONTROL WIRING TO INDOOR THERMOSTAT ROOF CURB INSTALLATION REAR DUCT SLAB ON GROUND INSTALLATION ROOF CURB INSTALLATION BOTTOM DUCT TYPICAL ROO...

Page 23: ...F CURB DIMENSIONS 8 roof curb also available UNIT BASE RAIL UNIT BASE WOOD NAILER 8 MIN ABOVE FINISHED ROOF CURB FRAME COUNTERFLASHING INSULATION CANT STRIP ROOF DECK AND ROOFING MATERIAL INSULATION A...

Page 24: ...PR 708 PR 716 PR 716 PR 713 PR 713 PR 710 PR 710 PR F6 F6 F4 F4 F2 F2 K6 K6 K4 K4 K5 K5 K3 K3 M1 M1 714 BK 714 BK 706 BK 706 BK 711 BK 711 BK 703 BK 703 BK 709 BK 709 BK F1 F1 F3 F3 F5 F5 DUAL POINT E...

Page 25: ...ts Group 25 036 21311 003 A 0104 TYPICAL WIRING DIAGRAM 230 3 60 POWER SUPPLY M R C COMPR RELAY DFST STAT M1 DETAIL A 222 Y BLU BLU DS DEFROST CONTROL 031 01268 000B FOR DEFROST CONTROL 031 09104 000A...

Page 26: ...R 2 1 2 R C T 1 1 0 9 B K 2 4 V 1 0 8 P R 4 8 0 O R 6 0 0 2 1 4 B R 8 D 7 E A B K 3 8 1 3 B R 8 1 4 Y L 2 L 2 L 2 1 2 3 H 1 L 1 L 1 L 1 K 1 2 0 9 R K 2 F A N C O N T R O L B O A R D T L H F L H 4 1 2...

Page 27: ...FAN MOTOR K2 RELAY ELECTRIC HEATER K3 RELAY ELECTRIC HEATER 24V DC COIL K7 RELAY LIMIT TRIP 24V DC COIL LP LOW PRESSURE SWITCH OPTIONAL ACCESSORY OPEN 7 PSIG LS LIMIT SWITCH ELECTRIC HEAT PART OF ELEC...

Page 28: ...uilding structure duct work and base unit 10 Condensate pan shall be internally sloped and conform to ASHRAE 62 89 self draining standards with 3 4 NPTI copper ridged mount connection INDOOR SUPPLY FA...

Page 29: ...tion with nickel chromium ele ments shall be provided in a range of 5 thru 25 KW offer ing two stages of capacity 7 KW and above on single phase heaters and one 20 KW and above on three phase heaters...

Page 30: ...30 Unitary Products Group 036 21311 003 A 0104...

Page 31: ...Unitary Products Group 31 036 21311 003 A 0104...

Page 32: ...Group 5005 York Drive Norman Oklahoma 73069 Subject to change without notice Printed in U S A Copyright by York International Corporation 2004 All Rights Reserved 036 21311 003 A 0104 Supersedes 036...

Reviews: