036-21528-001-A-0303

2

Unitary Products Group

CONDENSATE PAN

A  non-corrosive, long-lasting, water-tight pan is posi-

tioned below the evaporator coil to collect and drain all 

condensate; less collection of stagnate condensate will 

build-up. The condensate pan conforms to ASHRAE 

62-89 standards (Ventilation for Acceptable Indoor Air 

Quality).

CONDENSATE DRAIN

The heavy duty,  inch NPTI copper connection is more 

tolerable during installation and is more durable over 

time. The connection is rigidly mounted to assure 
proper fit and leak tight seal.

DURABLE FINISH

With a heavy duty cabinet made of powder-painted, 

galvanized steel, the neutral color blends into sur-

rounding areas. The powered paint provides a better 

paint to steel bond, which resists corrosion and rust 

creep. The special primer formulas and glossy earth 

tone finish insure less fading when exposed to sunlight 

and offers a more attractive on site appearance. This 

paint finish exceeds ASTM-B117 standards for 750 

hours salt spray rating, the highest in the industry.

FULL PERIMETER BASE RAILS

The easily removable base rails provide a solid founda-

tion for the entire unit and protects the unit during ship-

ment. The rails provide fork lift access from all sides.  

Rigging holes are, provided also so that an overhead 

crane can be used to place the unit on a roof. On appli-

cations when the unit is placed on a pad, the base will 

keep the unit off the pad to deter corrosion. On applica-

tions where height is limited, the 2-3/8 inch high base 

rails may be removed on location.

MORE ATTRACTIVE APPEARANCE

A single piece ìWater Shedî top cover containing a top 

discharge condenser fan arrangement requires less 

square footage on installation and provides a wider 

variety of installations. The one piece design adds 

greater water integrity. Rounded corners with water 

drip edges add to the attractive appearance. The cabi-

net panels have a non-fibrous insulation that reduces 

insulation fibers into conditioned area.

TOP DISCHARGE

The top discharge condenser fan does not disrupt 

neighboring areas and does not dry-out vegetation sur-

rounding the unit. The warm air from the top mounted 

fan is blown up away from the structure and any land-

scaping. This allows compact location on multi-unit 

applications.

OUTDOOR COIL GRILLE

A multi-piece totally enclosed, rigidly mounted outdoor 

coil grille provides protection from objects and person-

nel after installation.  It also provides protection during 
transit and installation.

LOW OPERATING SOUND LEVEL

The upward air flow carries the normal operating noise 

up and away from the living area. The rigid top panel 

effectively isolates any motor sound. Isolator mounted 

compressor and the rippled fins of the condenser coil, 

muffle the normal fan motor and compressor operating 

sounds. The unique formed base pan also aids in 

sound alterations with it's ìSuper-Structureî design. 

This design strategically places embossments in the 

pan for optimum strength and rigidity.

FAN SYSTEM

All models operate over a wide range of design condi-

tions with an (E.C.M.) electronically commutated motor 

that automatically adjusts the blower speed to meet a 

wide range of static requirements. These units easily 

match all types of applications and provides greater on 

site flexibility to match comfort requirements.

SIMPLE CONTROL CIRCUIT

A low voltage printed circuit board contains a low volt-

age terminal strip. The electrical control box is not 

located in the compressor compartment. All wiring 

internal to the unit is color/number coded.

CONTROLS

Reliable demand defrost control provides defrost. 

Defrost control also provides an ìXî terminal to provide 

a 24 volt signal for room thermostat ìLEDî indication of 

unit lockout, plus, built in 5 minute anti-short cycle pro-

tection.

Summary of Contents for B1HP024 THRU 048

Page 1: ...aller can fit this unit between the wheel wells of full size pick up truck All models are under 500 pounds All units are completely wired charged with R 22 and tested prior to shipment Unique test sta...

Page 2: ...er water integrity Rounded corners with water drip edges add to the attractive appearance The cabi net panels have a non fibrous insulation that reduces insulation fibers into conditioned area TOP DIS...

Page 3: ...1 leak rate Includes hood and mesh bird screen filter integrated into the hood dry bulb sensor and relief damper Sepa rate field accessories of single enthalpy and dual enthalpy are also available SIN...

Page 4: ...provide single phase models from factory furnished 40 VA trans former capability to 75 VA transformer capability ELECTRIC HEATERS Each heater package provides easy installation of elec tric heat strip...

Page 5: ...RIC HEAT NOMINAL CAPACITY KW 47 F 17 F MBH SEER EER MBH COP MBH COP SINGLE PHASE THREE PHASE 024 24 4 13 0 11 3 7 6 79 21 8 3 40 11 0 2 00 5 0 7 5 10 0 N A 030 30 0 13 0 11 3 7 6 77 28 2 3 40 16 5 2 2...

Page 6: ...R INPUT kW 2 20 2 21 2 17 2 16 2 24 2 24 2 20 2 19 Sensible Capacity MBH 1 Entering Dry Bulb F 86 19 5 21 5 20 5 20 6 20 4 22 3 20 8 20 9 83 17 2 19 2 20 5 20 6 18 5 20 7 20 8 20 9 80 14 9 16 9 19 7 2...

Page 7: ...ER INPUT kW 3 14 3 12 3 04 3 06 3 24 3 22 3 14 3 16 Sensible Capacity MBH 1 Entering Dry Bulb F 86 21 7 26 6 25 0 26 7 23 9 27 9 26 0 27 7 83 18 8 24 1 25 0 26 7 20 6 26 3 26 0 27 7 80 15 9 21 1 25 4...

Page 8: ...PUT kW 3 61 3 52 3 44 3 45 3 70 3 61 3 53 3 54 Sensible Capacity MBH 1 Entering Dry Bulb F 86 23 9 29 4 29 5 30 4 26 2 31 9 30 2 31 1 83 20 9 26 6 29 2 30 0 22 7 28 9 30 2 31 1 80 17 9 23 6 27 8 28 6...

Page 9: ...PUT kW 4 01 3 98 3 89 3 88 4 06 4 03 3 94 3 93 Sensible Capacity MBH 1 Entering Dry Bulb F 86 28 1 34 5 35 2 35 6 29 4 35 8 35 4 35 7 83 24 5 31 6 34 8 35 1 25 6 33 0 35 2 35 5 80 21 0 28 1 33 7 33 8...

Page 10: ...T kW 4 71 4 62 4 52 4 47 4 81 4 71 4 61 4 56 Sensible Capacity MBH 1 Entering Dry Bulb F 86 32 0 40 2 40 1 43 2 33 5 41 8 40 3 43 5 83 28 0 36 5 39 7 41 8 29 2 38 0 40 1 42 7 80 23 9 32 4 39 6 39 3 24...

Page 11: ...e indoor motor heat has been added These power inputs are total power inputs the indoor motor watts have been added TABLE 9 HEATING CAPACITIES 2 1 2 TON BHP030 CFM RETURN AIR F CAP1 KW OUTDOOR AIR TEM...

Page 12: ...the indoor motor heat has been added These power inputs are total power inputs the indoor motor watts have been added TABLE 11 HEATING CAPACITIES 3 1 2 TON BHP042 CFM RETURN AIR F CAP1 KW OUTDOOR AIR...

Page 13: ...KW 2 408 2 634 2 861 3 088 3 315 3 542 3 769 3 996 70 MBH 13 702 16 887 20 812 25 650 31 612 38 961 48 017 59 179 KW 2 792 3 018 3 245 3 472 3 699 3 926 4 153 4 380 80 MBH 12 114 15 299 19 224 24 062...

Page 14: ...CFM 273 324 392 480 541 B1HP042 Electric Heat 1225 CFM 306 341 412 494 577 B1HP042 Cooling TB2 A 1300 CFM 338 395 470 551 640 B1HP042 Cooling TB2 B 1400 CFM 393 466 544 642 734 B1HP042 Heating TB2 A...

Page 15: ...used for all field installed 24 volt wire Only required on units with supplemental electric heat PROGRAMMABLE THERMOSTAT ONLY 24 VOLT TRANSFORMER Label all wires prior to disconnection when servicing...

Page 16: ...15 0 96 75 036 208 230 1 60 187 253 17 2 94 0 1 1 7 3 29 9 45 45 0 96 40 208 230 3 60 187 253 11 4 78 0 1 1 7 3 22 7 30 30 0 96 75 460 3 60 414 504 5 7 40 0 0 6 7 3 15 4 20 20 0 96 75 042 208 230 1 60...

Page 17: ...06 7 5 10 0 36 1 41 7 83 2 90 1 90 100 90 100 2NP04501506 11 3 15 0 54 2 62 5 105 8 116 2 110 125 110 125 2NP04502006 15 0 20 0 72 2 83 3 128 3 142 2 150 150 150 150 2NP04502506 18 8 25 0 90 3 104 2 1...

Page 18: ...102 89 92 042 440 435 120 115 101 104 048 485 480 132 127 111 115 FIGURE 4 UNIT CLEARANCES CLEARANCES NOTE FOR UNITS APPLIED WITH A ROOF CURB THE MINIMUM CLE ARANCE MAY BE REDUCED FROM 1 INCH TO 1 2...

Page 19: ...036 21528 001 A 0303 Unitary Products Group 19 FIGURE 5 UNIT DIMENSIONS...

Page 20: ...036 21528 001 A 0303 20 Unitary Products Group FIGURE 6 TYPICAL APPLICATIONS...

Page 21: ...036 21528 001 A 0303 Unitary Products Group 21 FIGURE 7 ROOF CURB DIMENSIONS...

Page 22: ...036 21528 001 A 0303 22 Unitary Products Group FIGURE 8 TYPICAL WIRING DIAGRAM 208 230 1 60 POWER SUPPLY...

Page 23: ...036 21528 001 A 0303 Unitary Products Group 23 FIGURE 9 TYPICAL WIRING DIAGRAM 230 3 60 POWER SUPPLY...

Page 24: ...036 21528 001 A 0303 24 Unitary Products Group FIGURE 10 TYPICAL WIRING DIAGRAM 460 3 60 POWER SUPPLY...

Page 25: ...l be provided to assure reliable transit of equipment overhead rig ging fork truck access and proper sealing on roof curb applications Base rails shall be removable when required to lower unit height...

Page 26: ...pressures C Unit shall contain a reliable demand defrost control to provide defrost The defrost control shall also have an X terminal to provide a 24 volt signal for room thermostat LED indication of...

Page 27: ...036 21528 001 A 0303 Unitary Products Group 27...

Page 28: ...001 A 0303 Copyright by Unitary Products Group 2003 All rights reserved Supersedes Nothing Unitary 5005 Norman Products York OK Group Drive 73069 This product was manufactured in a plant whose qualit...

Reviews: