5331838-YTG-A-0317

6

Johnson Controls Unitary Products

APPLICATION & ACCESSORIES

Refer to Price Manual for specific model numbers.

Support Feet S1-HPRKIT-**:

 Kit of 5 support feet to raise unit

above snow or landscaping. Available in heights of 3", 6" or 12".

Anchor Bracket Kit S1-1HK0401:

 Firmly anchors unit to pad

or support structure. When properly installed, approved for
ground-mounted or roof-mounted applications.

Wall Mount Kit (S1-ACB-**):

 Includes two brackets to allow

outdoor unit to be securely mounted to a vertical wall. Mounting
hardware is field sourced according to the specific application.

Winter Cover Kit S1-CCVRE***:

 Custom fit winter cover pro-

tects AC  condensing  unit  from  debris  during  the  off-season.

Must be removed prior to unit operation. See Price Pages or
Source1 SmartSearch for the correct cover for each application

Touch-up Paint S1-5130153****:

 Color matched aerosol paint

for touching up unit chassis and panels. See Price Pages or
Source1 SmartSearch for the correct color for each application.

Thermostat:

 These advanced, communicating, variable capac-

ity designs require the York Hx™ Touchscreen Thermostat (S1-
THXU280) available through Source1. For more information,
see the thermostat section of the Product Equipment Catalog.

Rated in accordance with ARI Standard 270.

UNIT OPERATION

COOLING OPERATION

During cooling operation, the main outdoor control will receive a
communicated demand signal along with the current space
temperature and setpoint. The control algorithm will then utilize
these signals to communicate the proper compressor speed,
OD fan speed, and ID blower CFM to match system output for
the required space load.

EMERGENCY HEAT

Emergency Heating mode is defined as a compressor speed
reference of zero and the backup heat source energized. In
other words, a 'W' signal present without any 'Y' signals pres-
ent. The control energizes 'W1 OUT' immediately when an
emergency heat signal “W” is received. The control energizes
“W2 OUT” based upon the stage delay setting in the thermostat
(default 120 minutes) after the “W1 OUT” output is energized.

During emergency heating mode, the control returns to standby
mode. The control passes the “W1 OUT” back to the ID unit
automatically if no “Y” is present.

SOUND POWER RATINGS - COOLING

High Stage Cooling

Octave Band Sound Power Level (db re. 1-pW)

Model Numbers

63

125

250

500

1000

2000

4000

8000

dBA

SQI

YXV24B21S

67

69

65

68

63

59

57

53

69

19.1

YXV36B21S

71

75

69

71

69

65

59

53

73

19.1

YXV48B21S

72

73

71

71

69

64

59

54

73

19.2

YXV60B21S

75

76

73

72

70

65

61

55

74

19.0

Low Stage Cooling

Octave Band Sound Power Level (db re. 1-pW)

Model Numbers

63

125

250

500

1000

2000

4000

8000

dBA

SQI

YXV24B21S

63

64

52

49

46

42

33

36

53

19.0

YXV36B21S

63

64

55

59

55

50

42

37

60

19.1

YXV48B21S

64

64

72

53

50

42

36

35

64

19.1

YXV60B21S

64

65

59

56

54

49

42

38

59

19.1

Summary of Contents for AFFINITY SERIES YXV24 THRU 60

Page 1: ...high quality appearance Charge Assurance A built in touch screen instantly dis plays the system overall condition including the system pressures and refrigerant charge without the need to attach addi...

Page 2: ...nty Limited lifetime compressor warranty when registered online within 90 days of installa tion Agency Listed Safety certified by CSA to UL 1995 CSA 22 2 Performance certified to ANSI AHRI Standard 21...

Page 3: ...2 Rows Deep 1 1 2 2 Fins Inch 22 22 18 18 Liquid Line Set OD Field Installed 3 8 3 8 3 8 3 8 Vapor Line Set OD Field Installed 3 3 4 3 4 7 8 7 8 Unit Charge Lbs Oz 4 7 8 7 6 14 9 15 1 Charge Per Foot...

Page 4: ...stem charge without attaching a separate manifold gauge set or temperature sensors 6 Permanently mark the unit data plate with the total amount of refrigerant in the system SYSTEM CHARGE FOR VARIOUS M...

Page 5: ...is reduced until an acceptable current level is reached When the system reaches an acceptable current level the compres sor and fan return to normal operating conditions Over Under Voltage Protection...

Page 6: ...ERATION During cooling operation the main outdoor control will receive a communicated demand signal along with the current space temperature and setpoint The control algorithm will then utilize these...

Page 7: ...s shall be provided for field control wiring connections Service valves shall be provided for field refrig erant line connections Units shall be factory leak checked run tested and shipped with a hold...

Page 8: ...ount with center brace under center of compressor NOTE Ensure adequate wall support CAUTION Special care must be taken to avoid recirculation of discharge air through condenser coil CAUTION Care must...

Page 9: ...ay be reduced to 18 minimum provided the service access clearance is increased to 24 minimum and the clearance on each remaining side is maintained at 18 minimum NOTE Clearance to one side of the unit...

Page 10: ...9 16 5 18 4 14 2 15 0 15 3 16 8 18 8 KW 1 35 1 34 1 34 1 31 1 27 1 37 1 36 1 37 1 34 1 30 1 40 1 39 1 40 1 37 1 33 85 T C 19 9 21 1 21 4 24 3 27 1 20 4 21 8 22 3 24 9 28 0 20 9 22 5 23 2 25 5 29 0 S C...

Page 11: ...24 3 26 5 21 1 21 9 22 6 24 9 26 9 KW 2 02 2 02 2 02 2 00 1 93 2 07 2 07 2 07 2 05 1 98 2 12 2 12 2 12 2 10 2 04 85 T C 29 9 31 3 32 4 35 7 40 0 30 8 32 3 33 8 37 7 41 7 31 7 33 3 35 1 39 8 43 4 S C...

Page 12: ...2 35 3 31 0 30 1 29 8 32 7 35 5 KW 2 70 2 69 2 69 2 68 2 65 2 76 2 76 2 77 2 75 2 73 2 83 2 83 2 84 2 82 2 80 85 T C 41 5 42 9 43 2 47 7 52 9 43 2 43 9 44 0 48 5 53 6 45 0 45 0 44 8 49 3 54 2 S C 28...

Page 13: ...41 5 45 1 37 6 38 4 38 5 42 2 45 5 KW 3 65 3 69 3 68 3 70 3 72 3 76 3 78 3 78 3 79 3 82 3 86 3 87 3 87 3 88 3 91 85 T C 51 3 53 9 54 7 59 8 65 5 53 2 55 2 55 7 60 8 66 5 55 1 56 5 56 7 61 8 67 5 S C 3...

Page 14: ...ct to change without notice Published in U S A 5331838 YTG A 0317 Copyright 2017 by Johnson Controls Inc All rights reserved Supersedes Nothing York International Corp 5005 York Drive Norman OK 73069...

Reviews: