5331838-YTG-A-0317
6
Johnson Controls Unitary Products
APPLICATION & ACCESSORIES
Refer to Price Manual for specific model numbers.
Support Feet S1-HPRKIT-**:
Kit of 5 support feet to raise unit
above snow or landscaping. Available in heights of 3", 6" or 12".
Anchor Bracket Kit S1-1HK0401:
Firmly anchors unit to pad
or support structure. When properly installed, approved for
ground-mounted or roof-mounted applications.
Wall Mount Kit (S1-ACB-**):
Includes two brackets to allow
outdoor unit to be securely mounted to a vertical wall. Mounting
hardware is field sourced according to the specific application.
Winter Cover Kit S1-CCVRE***:
Custom fit winter cover pro-
tects AC condensing unit from debris during the off-season.
Must be removed prior to unit operation. See Price Pages or
Source1 SmartSearch for the correct cover for each application
Touch-up Paint S1-5130153****:
Color matched aerosol paint
for touching up unit chassis and panels. See Price Pages or
Source1 SmartSearch for the correct color for each application.
Thermostat:
These advanced, communicating, variable capac-
ity designs require the York Hx™ Touchscreen Thermostat (S1-
THXU280) available through Source1. For more information,
see the thermostat section of the Product Equipment Catalog.
Rated in accordance with ARI Standard 270.
UNIT OPERATION
COOLING OPERATION
During cooling operation, the main outdoor control will receive a
communicated demand signal along with the current space
temperature and setpoint. The control algorithm will then utilize
these signals to communicate the proper compressor speed,
OD fan speed, and ID blower CFM to match system output for
the required space load.
EMERGENCY HEAT
Emergency Heating mode is defined as a compressor speed
reference of zero and the backup heat source energized. In
other words, a 'W' signal present without any 'Y' signals pres-
ent. The control energizes 'W1 OUT' immediately when an
emergency heat signal “W” is received. The control energizes
“W2 OUT” based upon the stage delay setting in the thermostat
(default 120 minutes) after the “W1 OUT” output is energized.
During emergency heating mode, the control returns to standby
mode. The control passes the “W1 OUT” back to the ID unit
automatically if no “Y” is present.
SOUND POWER RATINGS - COOLING
High Stage Cooling
Octave Band Sound Power Level (db re. 1-pW)
Model Numbers
63
125
250
500
1000
2000
4000
8000
dBA
SQI
YXV24B21S
67
69
65
68
63
59
57
53
69
19.1
YXV36B21S
71
75
69
71
69
65
59
53
73
19.1
YXV48B21S
72
73
71
71
69
64
59
54
73
19.2
YXV60B21S
75
76
73
72
70
65
61
55
74
19.0
Low Stage Cooling
Octave Band Sound Power Level (db re. 1-pW)
Model Numbers
63
125
250
500
1000
2000
4000
8000
dBA
SQI
YXV24B21S
63
64
52
49
46
42
33
36
53
19.0
YXV36B21S
63
64
55
59
55
50
42
37
60
19.1
YXV48B21S
64
64
72
53
50
42
36
35
64
19.1
YXV60B21S
64
65
59
56
54
49
42
38
59
19.1