5331838-YTG-A-0317

2

Johnson Controls Unitary Products

Communications Capable –

 Requiring only 3 thermostat

wires between the outdoor and indoor units, the communi-
cating system provides self-commissioning on start-up as
well as the ability to check system status at the outdoor unit,
thermostat, or remotely using the designated App.

Variable Capacity Inverter Controlled Scroll Compressor

 Constantly monitors and dynamically adjusts system

capacity in precise increments as necessary to closely meet
the comfort demands of the conditioned space.

Advanced System Control –

 The proprietary wi-fi Hx™

thermostat interface is an integral part of this innovative sys-
tem design. Using the Consumer App, consumers can moni-
tor and adjust their system from anywhere in the world using
a smart device. Contractors can use the Service App (with
homeowner permission), to monitor the system remotely and
make adjustments as needed. The system can be configured
to provide alerts for emerging issues as well as items that
require immediate attention.

Premium System Warranty* -

 Limited lifetime compressor

warranty when registered online within 90 days of installa-
tion.

Agency Listed –

 Safety certified by CSA to UL 1995 / CSA

22.2. Performance certified to ANSI/AHRI Standard 210/240
in accordance with the Unitary Small Equipment certification
program.

LIST OF SECTIONS

DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
FEATURES   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
LIST OF SECTIONS   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
NOMENCLATURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
PHYSICAL AND ELECTRICAL DATA  . . . . . . . . . . . . . . . . . . . . . . . 3
DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
SYSTEM CHARGE FOR VARIOUS MATCHED SYSTEMS . . . . . . . 4
LIMITATIONS   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
SYSTEM CAPACITY - Single Piece and Modular Air Handlers   . . 5
APPLICATION & ACCESSORIES   . . . . . . . . . . . . . . . . . . . . . . . . . . 6
SOUND POWER RATINGS - COOLING . . . . . . . . . . . . . . . . . . . . . . 6
UNIT OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
MECHANICAL SPECIFICATIONS   . . . . . . . . . . . . . . . . . . . . . . . . . . 7
TYPICAL INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
TYPICAL FIELD WIRING   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
ALTERNATIVE INSTALLATION CLEARANCES . . . . . . . . . . . . . . . 9
PERFORMANCE DATA - 2 TON   . . . . . . . . . . . . . . . . . . . . . . . . . . 10
PERFORMANCE DATA - 3 TON   . . . . . . . . . . . . . . . . . . . . . . . . . . 11
PERFORMANCE DATA - 4 TON   . . . . . . . . . . . . . . . . . . . . . . . . . . 12
PERFORMANCE DATA - 5 TON   . . . . . . . . . . . . . . . . . . . . . . . . . . 13

NOMENCLATURE

BRAND

Y

Y

 = York

PRODUCT TYPE

X

 X = Premium Air Conditioner

NOMINAL
SERIES EFFICIENCY
AND STAGING

V

 V = 20 SEER / Modulating

NOMINAL UNIT
CAPACITY (MBH)

36

24

 = 2 Ton

48

 = 4 Ton

36

 = 3 Ton

60

 = 5 Ton

REFRIGERANT

B

B

 = R-410A

VOLTAGE
(Voltage-Phase-Hertz)

2

2

 = 208/230-1-60

GENERATION
(MAJOR REVISION)

1

1

 = 1st Gen

2

 = 2nd Gen

etc

FACTORY OPTION

S

S

 = Standard (No Options)

H

 = Hard Start Kit

STYLE LETTER
(MINOR REVISION)
NOT USED 
FOR ORDERING

A

A

 = Style A

B

 = Style B

etc.

Summary of Contents for AFFINITY SERIES YXV24 THRU 60

Page 1: ...high quality appearance Charge Assurance A built in touch screen instantly dis plays the system overall condition including the system pressures and refrigerant charge without the need to attach addi...

Page 2: ...nty Limited lifetime compressor warranty when registered online within 90 days of installa tion Agency Listed Safety certified by CSA to UL 1995 CSA 22 2 Performance certified to ANSI AHRI Standard 21...

Page 3: ...2 Rows Deep 1 1 2 2 Fins Inch 22 22 18 18 Liquid Line Set OD Field Installed 3 8 3 8 3 8 3 8 Vapor Line Set OD Field Installed 3 3 4 3 4 7 8 7 8 Unit Charge Lbs Oz 4 7 8 7 6 14 9 15 1 Charge Per Foot...

Page 4: ...stem charge without attaching a separate manifold gauge set or temperature sensors 6 Permanently mark the unit data plate with the total amount of refrigerant in the system SYSTEM CHARGE FOR VARIOUS M...

Page 5: ...is reduced until an acceptable current level is reached When the system reaches an acceptable current level the compres sor and fan return to normal operating conditions Over Under Voltage Protection...

Page 6: ...ERATION During cooling operation the main outdoor control will receive a communicated demand signal along with the current space temperature and setpoint The control algorithm will then utilize these...

Page 7: ...s shall be provided for field control wiring connections Service valves shall be provided for field refrig erant line connections Units shall be factory leak checked run tested and shipped with a hold...

Page 8: ...ount with center brace under center of compressor NOTE Ensure adequate wall support CAUTION Special care must be taken to avoid recirculation of discharge air through condenser coil CAUTION Care must...

Page 9: ...ay be reduced to 18 minimum provided the service access clearance is increased to 24 minimum and the clearance on each remaining side is maintained at 18 minimum NOTE Clearance to one side of the unit...

Page 10: ...9 16 5 18 4 14 2 15 0 15 3 16 8 18 8 KW 1 35 1 34 1 34 1 31 1 27 1 37 1 36 1 37 1 34 1 30 1 40 1 39 1 40 1 37 1 33 85 T C 19 9 21 1 21 4 24 3 27 1 20 4 21 8 22 3 24 9 28 0 20 9 22 5 23 2 25 5 29 0 S C...

Page 11: ...24 3 26 5 21 1 21 9 22 6 24 9 26 9 KW 2 02 2 02 2 02 2 00 1 93 2 07 2 07 2 07 2 05 1 98 2 12 2 12 2 12 2 10 2 04 85 T C 29 9 31 3 32 4 35 7 40 0 30 8 32 3 33 8 37 7 41 7 31 7 33 3 35 1 39 8 43 4 S C...

Page 12: ...2 35 3 31 0 30 1 29 8 32 7 35 5 KW 2 70 2 69 2 69 2 68 2 65 2 76 2 76 2 77 2 75 2 73 2 83 2 83 2 84 2 82 2 80 85 T C 41 5 42 9 43 2 47 7 52 9 43 2 43 9 44 0 48 5 53 6 45 0 45 0 44 8 49 3 54 2 S C 28...

Page 13: ...41 5 45 1 37 6 38 4 38 5 42 2 45 5 KW 3 65 3 69 3 68 3 70 3 72 3 76 3 78 3 78 3 79 3 82 3 86 3 87 3 87 3 88 3 91 85 T C 51 3 53 9 54 7 59 8 65 5 53 2 55 2 55 7 60 8 66 5 55 1 56 5 56 7 61 8 67 5 S C 3...

Page 14: ...ct to change without notice Published in U S A 5331838 YTG A 0317 Copyright 2017 by Johnson Controls Inc All rights reserved Supersedes Nothing York International Corp 5005 York Drive Norman OK 73069...