LIMITATIONS

The unit should be installed in accordance with all National, State and
Local Safety Codes and the limitations listed below:

1. Limitations for the indoor unit, coil, and appropriate accessories

must also be observed.

2. The outdoor unit must not be installed with any duct work in the air

stream. The outdoor fan is the propeller type and is not designed to
operate against any additional external static pressure.

3. The maximum and minimum conditions for operation must be

observed to ensure a system will give maximum performance with
minimal service.

4. The maximum allowable equivalent line length for this product is 80

feet.

Standard Lineset Applications

Maximum allowable lineset varies depending on the vertical separation
between the evaporator and condenser. See Table 2 for allowable line
set lengths and sizing. 

Unit Reduced Capacity Conditions

— = Not applicable.
CM coils available with a factory installed horizontal drain pan. See price pages for specific model number.

TABLE 1: Minimum / Maximum Operating Limit Conditions

AIR TEMPERATURE AT 

OUTDOOR COIL, ° F (° C)

AIR TEMPERATURE AT 

INDOOR COIL, ° F (° C)

Min.

Max.

Min.

Max.

DB Cool

DB Cool

WB Cool

WB Cool

35(2)*

125(52)*

57(14)

72(22)

*

Reference the NOTICE under the “Unit Reduced Capacity Conditions” 

 section.

TABLE 2: Allowable Vertical Linesets.

Model

Liquid 

Line

Suction 

Line

Max Line 

Length - 
Units on 

Equal Level

Max Suction 

Line Riser - If 

OD Unit is 

Above ID Unit

Max Liquid 

Line Riser - If 

OD Unit is 

Below ID Unit

24

3/8”

3/4”

80 feet

25 feet

25 feet

36

48

7/8”

60

NOTICE

Inverter Temperature Protection: 
If excessive inverter temperatures are sensed, the compressor speed
/ capacity is reduced until an acceptable condition is reached. 
When the inverter temperature returns to an acceptable level, the
system returns to normal operation.
Over / Under Current Protection: If a low or high Current Condition
is sensed, the compressor speed / capacity is reduced until an
acceptable current level is reached.
When the system reaches an acceptable current level, the compres-
sor and fan return to normal operating conditions.
Over / Under Voltage Protection: If a low or high supply Voltage
Condition is experienced (below 187 VAC or above 265 VAC), the
compressor speed / capacity is automatically reduced until an accept-
able voltage level is sensed.
When an acceptable voltage level is sensed, the system automati-
cally returns to a normal state of operation.
High Altitude Protection: If the unit is installed in Altitudes of 6,500
ft / 2,000 m above sea level or higher, the compressor and outdoor
fan reduce speeds to protect the system. It is not recommended
these units be installed at altitudes greater than 6,500 ft / 2,000 m
above sea level. 
Low Ambient Protection:
Cooling Mode:
 The unit automatically adjusts to maintain cooling
operation in outdoor ambient conditions down to 35° F (2° C). The
unit reduces capacity and Low Ambient Protection (cooling mode) or
cycles off if asked to provide cooling when the outdoor temperature is
at or below these conditions. 

SYSTEM CAPACITY - Single Piece and Modular Air Handlers 

UNIT 

MODEL

AIR HANDLER

COIL

MODEL

3

Stage

RATED

CFM

COOLING 

1

1. Cooling MBH based on 80°

F entering air temperature, 50% RH (Relative Humidity), and rated air flow.

EER (Energy Efficiency Ratio) is the total cooling output in BTUs at 95°

F outdoor ambient divided by the total electric power in watt-hours at those conditions.

SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTUs during a normal annual usage period for cooling divided by the total electric power 
input in watt-hours during the same period.

MODEL

WIDTH

NET MBH

SEER

EER

TOTAL

SENS.

YXV24B21S

AVV25BE121

17.5

High

775

23.4

17.7

19.25

14.00

Med

500

14.1

11.2

-

18.50

Low

350

10.0

7.9

-

34.30

YXV36B21S

AVV37CE221

21.0

High

1200

35.0

25.8

19.00

13.25

Med

700

19.0

14.6

-

18.00

Low

400

11.2

8.9

-

33.00

YXV48B21S

AVV49DE321

24.5

High

1500

45.5

34.2

19.50

13.00

Med

800

25.2

18.5

-

19.10

Low

500

14.9

11.5

-

36.20

YXV60B21S

AVV61DE421

24.5

High

1600

52.5

38.5

20.00

13.00

Med

1000

30.4

23.4

-

19.10

Low

700

20.8

16.6

-

36.25

Summary of Contents for AFFINITY SERIES YXV24 THRU 60

Page 1: ...high quality appearance Charge Assurance A built in touch screen instantly dis plays the system overall condition including the system pressures and refrigerant charge without the need to attach addi...

Page 2: ...nty Limited lifetime compressor warranty when registered online within 90 days of installa tion Agency Listed Safety certified by CSA to UL 1995 CSA 22 2 Performance certified to ANSI AHRI Standard 21...

Page 3: ...2 Rows Deep 1 1 2 2 Fins Inch 22 22 18 18 Liquid Line Set OD Field Installed 3 8 3 8 3 8 3 8 Vapor Line Set OD Field Installed 3 3 4 3 4 7 8 7 8 Unit Charge Lbs Oz 4 7 8 7 6 14 9 15 1 Charge Per Foot...

Page 4: ...stem charge without attaching a separate manifold gauge set or temperature sensors 6 Permanently mark the unit data plate with the total amount of refrigerant in the system SYSTEM CHARGE FOR VARIOUS M...

Page 5: ...is reduced until an acceptable current level is reached When the system reaches an acceptable current level the compres sor and fan return to normal operating conditions Over Under Voltage Protection...

Page 6: ...ERATION During cooling operation the main outdoor control will receive a communicated demand signal along with the current space temperature and setpoint The control algorithm will then utilize these...

Page 7: ...s shall be provided for field control wiring connections Service valves shall be provided for field refrig erant line connections Units shall be factory leak checked run tested and shipped with a hold...

Page 8: ...ount with center brace under center of compressor NOTE Ensure adequate wall support CAUTION Special care must be taken to avoid recirculation of discharge air through condenser coil CAUTION Care must...

Page 9: ...ay be reduced to 18 minimum provided the service access clearance is increased to 24 minimum and the clearance on each remaining side is maintained at 18 minimum NOTE Clearance to one side of the unit...

Page 10: ...9 16 5 18 4 14 2 15 0 15 3 16 8 18 8 KW 1 35 1 34 1 34 1 31 1 27 1 37 1 36 1 37 1 34 1 30 1 40 1 39 1 40 1 37 1 33 85 T C 19 9 21 1 21 4 24 3 27 1 20 4 21 8 22 3 24 9 28 0 20 9 22 5 23 2 25 5 29 0 S C...

Page 11: ...24 3 26 5 21 1 21 9 22 6 24 9 26 9 KW 2 02 2 02 2 02 2 00 1 93 2 07 2 07 2 07 2 05 1 98 2 12 2 12 2 12 2 10 2 04 85 T C 29 9 31 3 32 4 35 7 40 0 30 8 32 3 33 8 37 7 41 7 31 7 33 3 35 1 39 8 43 4 S C...

Page 12: ...2 35 3 31 0 30 1 29 8 32 7 35 5 KW 2 70 2 69 2 69 2 68 2 65 2 76 2 76 2 77 2 75 2 73 2 83 2 83 2 84 2 82 2 80 85 T C 41 5 42 9 43 2 47 7 52 9 43 2 43 9 44 0 48 5 53 6 45 0 45 0 44 8 49 3 54 2 S C 28...

Page 13: ...41 5 45 1 37 6 38 4 38 5 42 2 45 5 KW 3 65 3 69 3 68 3 70 3 72 3 76 3 78 3 78 3 79 3 82 3 86 3 87 3 87 3 88 3 91 85 T C 51 3 53 9 54 7 59 8 65 5 53 2 55 2 55 7 60 8 66 5 55 1 56 5 56 7 61 8 67 5 S C 3...

Page 14: ...ct to change without notice Published in U S A 5331838 YTG A 0317 Copyright 2017 by Johnson Controls Inc All rights reserved Supersedes Nothing York International Corp 5005 York Drive Norman OK 73069...