Noise  might  be  regulated  under  laws  and  regulations  of  the  country  or  regions  where  the  product  is 

used.

】 

The tool must be used at noise levels below those prescribed by them. Install sound insulation walls, 

depending on the necessity. 

If noise levels at the operator’s position exceed 85dB (A), be sure to use earplugs. Even if noise levels 

are not more than 85dB (A), it is recommended to use earplugs.

 

Do not install this product in a place likely to be exposed to water, direct sunlight, much dust, heat, oil, or 

moving parts of industrial equipment. Otherwise, it may cause fire, electric shock, or accident. 

 

1.2.  Electrical Safety 

  Warning

 

This product is for the indoor exclusive use.    Do not use it in rain, in a damp place and a wet place. 

Moreover, never use it in the place with the fear of the ignition and the explosion, because those are 

hazardous situation.

 

Do not hold the power supply cord for battery charger for carrying or pull the cord to unplug it. In addition, 

be careful to avoid stepping on or being caught by the cord, and/or damage by excessive force. Damage 

of the power supply cord may result in accident. 

Do not insert the power supply cord of the battery charger between the objects to be tightened or contact 

it with rotating parts. Otherwise, it may be damaged and cause accident.   

  Use the exclusive battery pack and battery charger only.   

Failure to do so may result in rupture of it and damage of the product or property. 

Use the battery charger at rated supply voltage (AC 100-240 V).   

Do not use DC power supply, engine generator, or power transformer. Failure to do so may result in heat 

generation and fire. 

Do not disassemble or modify the battery pack and battery charger.   

Doing so may result in heat generation, fire, electric shock, or injury. 

Do not throw the battery pack into fire or heat it.   

Doing so may result in rupture or release of hazardous substances.   

Do not drive a nail or give an impact such as fall on the battery pack or battery charger.   

Doing so may result in heat generation, fire, electric shock, and/or injury. 

Do not short-circuit the terminals of the battery pack.   

Do not carry or store the battery pack with metal object such as nail. Doing so may result in smoking, 

ignition, or rupture. 

If the battery pack gets hot during its use, stop using it immediately and contact your sales outlet or sales 

agent.   

If the battery pack leaks, stop using it and contact your sales outlet or sales agent.   

Be sure to fully insert the power plug of the battery charger.   

Failure to do so may result in electric shock or fire due to heat generation. 

Summary of Contents for YS-e600

Page 1: ...rchasing YOKOTA products Before use please read this Instruction Manual carefully and use the product properly after fully understanding the Manual Please be sure to keep this Instruction Manual YOKOT...

Page 2: ...2 SPECIFICATION 10 3 EACH PART DESCRIPTION 12 4 REPARATIONS BEFORE USE 14 5 PAIRING 15 6 SINGLE OPERATION MODE 17 7 FUNCTIONS OF THROTTLE LEVER AND REVERSE LEVER 18 8 METHOD OF ADJUSTMENT OF OUTPUT 18...

Page 3: ...t this Instruction Manual or the warning label affixed to the product or made it dirty immediately contact us or your YOKOTA representative to obtain the Manual or the warning label and then properly...

Page 4: ...the battery charger between the objects to be tightened or contact it with rotating parts Otherwise it may be damaged and cause accident Use the exclusive battery pack and battery charger only Failure...

Page 5: ...in serious personal injury To protect yourself wear personal protective equipment such as a hard hat helmet safety glasses safety shoes And depending on work environment wear earplugs a dust mask etc...

Page 6: ...on the attachment and or early malfunction of the product as well as accidents Use socket stoppers specified by Yokota or socket makers Do not use wire a nail and others as a substitute for a socket s...

Page 7: ...ed stop using it immediately In addition to avoid the use of the damaged tool identify it as damaged and separate it from normal ones If you feel uneasiness during the use stop using the tool immediat...

Page 8: ...the following inspections on No damage of hooking parts such as balancer and correct mounting condition No damage on hanger 1 5 Maintenance Inspection and Repair Warning Before maintenance inspedtion...

Page 9: ...in shaft If the warming up is not carried out slip phenomenon may occur pulses may not generate In cold location or before starting the work in winter season use fully charged battery pack If the batt...

Page 10: ...2 Sound pressure level LPA 72dB 72dB 76dB 78dB 78dB 78dB Uncertainty KPA 3dB 3dB 3dB 3dB 3dB 3dB Total of values for three measured axes of vibration EN60745 2 2 3 2 5 2 2 5 2 2 5 2 2 5 2 2 5 2 2 5 2...

Page 11: ...ns 76mm W 119mm D 45mm H Weight 0 41kg Ambient operating temperature 0 40 Battery Charger Model BC0075G Rated input voltage AC100 240V 10 50 60Hz Rated charging current 2A 1 External dimensions 200mm...

Page 12: ...Buzzer built in Buzzer to inform the worker of tightening OK occurrence of error etc Pairing button built in Button to do pairing with the wireless unit Cooling fan built in Fan to cool motor section...

Page 13: ...p and indicate the level of the battery pack Guide for battery level 3 LEDs lighting Not less than 75 2 LEDs lighting 30 to 75 One LED lighting 5 to 30 charge the battery pack as soon as possible Anti...

Page 14: ...led the LED lights in red and the charging starts When the charging is completed the LED lights in green 4 2 3 Remove the battery pack from the battery charger 4 2 4 Remove the power plug of the batte...

Page 15: ...rottle lever It beeps and the tool is activated 5 3 Press the pairing button of the wireless unit for a while Press the button until the LED of TOOL1 of the wireless unit lights up in red 5 4 Press th...

Page 16: ...nly one blinking If the pairing is not done it blinks in yellow repeated blinking 5 7 When the LED of the tool lights in red and goes off the pairing is completed The wireless unit transmits the set v...

Page 17: ...ll data such as tightening results tightening waveforms are not stored To release the single operation mode remove and insert 6 1 Install the battery into the tool 6 2 While the pressing the pairing b...

Page 18: ...lever the main shaft rotates right If you press its L side and pull the throttle lever the main shaft rotates left While the main shaft rotates do not operate the reverse lever 8 Method of adjustment...

Page 19: ...ual 76 QD0444EN 00Y01 00 doc 19 9 Accessories Item When mounted Protector 1 For YS e600 White For YS e800 Blue For YS e900 Black TF pin 2 90 1 1 For protector and TF pin 2 90 use the parts specified b...

Page 20: ...is failed OFF Lighting in purple When tightening is OK The buzzer beeps Lighting in green OFF until the following conditions are met 1 second elapsed next buzzer sound operation of the throttle lever...

Page 21: ...The tool needs repair Commutation error Red rapid flashing The lighting patterns as stated in the right column are displayed while the pairing button is pressed Repeating red ON purple ON greenON OFF...

Page 22: ...mode Press the pairing button of the wireless unit for a while until the wireless unit shifts to pairing mode The distance between the tool and the wireless unit is long Get the tool and the wireless...

Page 23: ...ttery pack Replace the battery pack No lighting of Indicator lamp for the status of charging red of the battery charger Dust adheres to the terminals of the battery charger and the battery pack Clean...

Reviews: