YPP6830 Pulse Input Rate/Totalizer
Instruction Manual
8
POWER OPTIONS
9-30 VDC Powered, 2.2 W max
4-20 mA Output Powered, 30 VDC max
Battery Power
9-30 VDC Powered with Battery Backup
4-20 mA Output Powered with Battery Backup
BATTERY
3.6 V Primary Lithium (Li-SOCl
2
), non-rechargeable
Model YPPABAT36C
Expected Service Life & Recommended Replacement Interval
Operating Condition
Estimated
Service
Life
Suggested
Replacement
Interval
Open collector outputs off,
Through-Glass buttons off,
minimal backlight use
7.5 years
5.5 years
<100 Hz open collector outputs,
minimal Through-Glass button or
backlight use
5.5 years
4 years
<2 kHz open collector outputs,
minimal Through-Glass button or
backlight use
2.5 years
2 years
<5 kHz open collector outputs,
minimal Through-Glass button or
backlight use
1.3 years
1 year
Backup power only
N/A
10 years
DATA LOGGING
Up to 1024 records, recorded 4/day at specific times or at
defined time intervals. Record contains date, time, rate, total,
grand total, and log number.
ISOLATION
All Models:
500 V opto-isolated input-to-power/output with
isolated input enabled
YPP6830-
BTA:
500 V input-to-output
YPP6830-
APA:
500 V input/power-to-output
Note: Requires separate output supply
ENVIRONMENTAL
Operating temperature range: -40 to 75°C
Storage temperature range: -40 to 75°C
Backlight deactivated below temperatures
≈
-20°C
Relative humidity: 0 to 90% non-condensing