YPP6830 Pulse Input Rate/Totalizer
Instruction Manual
11
TOTAL & GRAND
TOTAL DISPLAY
UNITS
Gallons, liters, imperial gallons, cubic meters, barrels,
bushels, cubic yards, cubic feet, cubic inches, liquid barrels,
beer barrels, hectoliters, or custom. Setting is independent
for each.
TOTAL & GRAND
TOTAL DISPLAY
UNIT MULTIPLIER
x1, x100 (h), x1000 (k), or x1,000,000 (M) multiplier (and
prefix) applied to total or grand total display units. Setting is
independent for each.
TOTAL & GRAND
TOTAL DECIMAL
POINT
Up to six decimal places or none:
6.666666
,
55.55555
,
444.4444
,
3333.333
,
22222.22
,
111111.1
or
0000000
Total and grand total decimal points are independently
programmed, and are independent of rate decimal point.
TOTALIZERS
Calculates total and grand total based on rate and field
programmable multiplier to display total in engineering
units. Time base must be selected according to the time
units in which the rate is displayed. The total and grand
total utilize the same time base, with different conversion
factors and resets.
TOTALIZER
RESET
Via Through-Glass RESET button, mechanical button (cov-
er off), external contact closure (total only), automatically
via user selectable preset value and time delay (1 – 99,999
sec). Manual reset may be disabled or protected by pass-
word for the total and grand total. Total and grand total
reset independently.
TOTAL
OVERFLOW AND
ROLLOVER
The total can display up to 9,999,999,999,999. Up to
9,999,999 can be displayed on the lower display normally.
An overflow display will toggle between the first six digits
and last seven digits (999999 <> 9999999) for a 13-digit
total. The total will rollover beyond thirteen digits. The T
indicator on the display will flash to indicate total overflow,
and the six most significant digits (first six numbers of the
total) are indicated with the flashing overflow symbol .
GRAND TOTAL
OVERFLOW AND
ROLLOVER
The grand total can display up to 9,999,999,999,999. Up to
9,999,999 can be displayed on the lower display normally.
An overflow display will toggle between the first six digits
and last seven digits (999999 <> 9999999) for a 13-digit
total. The grand total will rollover beyond thirteen digits. The
GT indicator on the display will flash to indicate grand total
overflow, and the six most significant digits (first six num-
bers of the grand total) are indicated with the flashing over-
flow symbol .
EXTERNAL
TOTAL RESET
External total reset connections are made between RST and
COM. Logic High: 1.4 V, 3.3V max; Logic Low: < 0.8 V.
32 ms debounce.