13. General Specifications
>
13-2
IM 01S01C01-01EN
13.2 Physical Specifications
Enclosure
Material
Housing:
• Low copper cast aluminum alloy
• ASTM CF-8M Stainless steel (optional)
Coating of housing
[for aluminum housing]
Urethane curing type polyester resin powder
coating
Mint-green paint (Munsell 5.6BG 3.3/2.9 or its
equivalent)
[for option code /P
or /X2]
Epoxy and polyurethane resin solvent coating
Body: 316L SST
Scroll Knob: 316L SST
Cover O-rings: Buna-N
Name plate and tag: 316 SST
Degrees of Protection
IP66/IP67, Type 4X
Weight
1.2 kg (2.6 lb) *
*: Without mounting bracket.
Add 1.5 kg (3.3 lb) for Amplifier housing code 2.
Electrical Connections
Refer to 13.3 Model and Suffix Codes.
13.3 Model and Suffix Codes
Model
Suffix code
Description
FVX110
. . . . . . . . . . . . . . . . . . . .
Fieldbus segment indicator
Output signal
-F . . . . . . . . . . . . . . . . . .
Digital communication (FOUNDATION Fieldbus protocol)
Amplifier housing
1 . . . . . . . . . . . . . . . .
2 . . . . . . . . . . . . . . . .
Cast aluminum alloy
ASTM CF-8M stainless steel
*1
Electrical connection 0 . . . . . . . . . . . . .
G 1/2 female, one electrical connection without blind plug
2 . . . . . . . . . . . . .
1/2 NPT female, two electrical connections without blind plugs
4 . . . . . . . . . . . . .
M20 female, two electrical connections without blind plugs
5 . . . . . . . . . . . . .
G 1/2 female, two electrical connections and a blind plug
7 . . . . . . . . . . . . .
1/2 NPT female, two electrical connections and a blind plug
9 . . . . . . . . . . . . .
M20 female, two electrical connections and a blind plug
A . . . . . . . . . . . .
G 1/2 female, two electrical connections and a 316 SST blind plug
D . . . . . . . . . . . .
1/2 NPT female, two electrical connections and a 316 SST blind plug
C . . . . . . . . . . . .
M20 female, two electrical connections and a 316 SST blind plug
Mounting bracket
L . . . . . . . . . .
316 SST 2-inch pipe mounting
N . . . . . . . . . .
None
Optional Codes
/
Optional Specification
*1: Not applicable for electrical connection code 0, 5, 7 or 9
Summary of Contents for FVX110
Page 1: ...User s Manual FVX110 Fieldbus Segment Indicator IM 01S01C01 01EN IM 01S01C01 01EN 4th Edition ...
Page 15: ... 2 Handling Cautions 2 4 IM 01S01C01 01EN ...
Page 16: ... 2 Handling Cautions 2 5 IM 01S01C01 01EN ...
Page 17: ... 2 Handling Cautions 2 6 IM 01S01C01 01EN ...
Page 18: ... 2 Handling Cautions 2 7 IM 01S01C01 01EN ...
Page 19: ... 2 Handling Cautions 2 8 IM 01S01C01 01EN ...