IM 85A7C03-16E
3-5
<3. Overview>
⚫
Certifications (FC33E)
ATEX Certificated:
CML 14 ATEX 1097Xx1
Equipment intended for use in Potentially Explosive Atmospheres Directive 2014/34/EU
Equipment
FC33E*** Pan & Tilt CCTV Cameras
EN 60079-0:2018, EN 60079-1:2014, EN 60079-31:2014
Type of Protection and Marking code:
Ex d
b IIC T5 Gb
Ex tb IIIC T100°C Db
FC33E-***1*/*: Ambient Temperature: -40°C to +60°C
FC33E-***1*/*: Rating: 100VAC to 240VAC ~0.6A 50/60Hz
IECEx Certificate of Conformity
IECEx CML 16.0096X
Equipment:
FC33E*** Pan & Tilt CCTV Cameras
Type of Protection:
Flameproof "d
b", Dust Ingition "tb"
Marking
Ex d
b IIC T5 Gb
Ex tb IIIC T100°C Db
Ta = -40°C to +60°C
Standards:
IEC 60079-0:2017 Edition 7.0, IEC 60079-1:2014-06 Edition 7.0, IEC 60079-31:2013 Edition 2
CSA Explosion-proof approval:
Certificate 80009215
Type Designation
FC33E - * a b c * /*
PRODUCTS
FC33E - ***2*/*:
(
Where,
2
above:
CSA CERTIFICATION)
CLASS 2258 02 - PROCESS CONTROL EQUIPMENT - For Hazardous Locations
Ex d
b IIC T5 Gb
Rated 100 Vac to 240 Vac, 50/60 Hz, ambient range: -40°C to 60°C
Pan Tilt Zoom Type CCTV Cameras Models FC33E***
APPLICABLE REQUIREMENTS:
CAN/CSA-C22.2 No. 60079-0:19, CAN/CSA-C22.2 No. 60079-1:16, CAN/CSA-C22.2 No. 61010-1-12,
CSA C22.2 No. 94.2-15
CONDITIONS OF ACCEPTABILITY:
1. The above models are permanently connected,
Equipment Class I, Pollution Degree 2, Overvoltage Category II
2. Mode of operation:
Continuous
3. Environmental Conditions: -40 to 60°C, 2000 m max., 20 to 95% RH
4. This equipment employs flame
path joints that have not been tested at the maximum joint dimensions
and minimum flame
path lengths permitted by the standard.
When the equipment is to be repaired, maintained or inspected, contact the manufacturer for
information on dimensions.
5. Installation must comply with Canadian Electrical Code wiring method for Zone 1.
NOTES:
1. For Canadian Installations, housing of the Base box must be bonded to ground according to Section
18 of the CEC, Part 1
*
Summary of Contents for FIELDEYE II Series
Page 9: ...IM 85A7C03 16E Blank Page...
Page 25: ...IM 85A7C03 16E Blank Page...
Page 59: ...IM 85A7C03 16E Blank Page...
Page 93: ...IM 85A7C03 16E Blank Page...
Page 99: ...IM 85A7C03 16E Blank Page...
Page 101: ...IM 85A7C03 16E Blank Page...
Page 103: ...IM 85A7C03 16E Blank Page...
Page 107: ...IM 85A7C03 16E Blank Page...