28
IM FG410-01EN
4. BASIC OPERATION
b) Restoration of settings during power supply on/off
This applies to switching the power supply on/off at one time for this equipment and other embedded
devices when this equipment is mounted in a rack.
When the power supply is cut off while the equipment power is on, the equipment power
automatically goes on the next time the power supply is reconnected.
設定
AAA
設定
BBB
設定
MMM
1
2
1
設定
MMM
2
LINE
LINE
LINE
LINE
LINE
LINE
Power supply connected
Power supply disconnected
Power on state
The power is switched off
Power supply connected
Power supply reconnected
Power supply reconnected
Power on state
The power is switched on.
(The settings are set to thecontents
of setting memory 1.)
Setting change
procedure
Power supply disconnected
The power is switched on.
(The settings are set to thecontents
of setting memory 1.)
The power is switched off
• The settings before the power is switched off cannot be restored.
• The contents of setting memory number 1 are set.
• The output on/off settings at power-on can be set on the Utility screen.
Check
Since the settings before the power supply is cut off are not restored, specify the
contents of setting memory number 1 beforehand if required.
p. 126
Summary of Contents for FG420
Page 10: ...VIII IM FG410 01EN...
Page 165: ...151 IM FG410 01EN External dimensions FG410 Unit mm 7 17 General Characteristics...
Page 166: ...152 IM FG410 01EN 7 SPECIFICATIONS External dimensions FG420 Unit mm...
Page 168: ...154 IM FG410 01EN 7 SPECIFICATIONS Inch rack mounting dimensions for 2 units Unit mm...
Page 170: ...156 IM FG410 01EN 7 SPECIFICATIONS Millimeter rack mounting dimensions for 2 units Unit mm...
Page 171: ...157 IM FG410 01EN 7 17 General Characteristics...
Page 173: ...159 IM FG410 01JA...
Page 178: ......
Page 179: ......