IM 01E20D01-01E
6-24
6. OUTLINE
REPLACEMENT MODEL FOR EARLIER ADMAG OR ADMAG AE (Flange Type)
General-purpose Use/Submersible Type/Explosion proof Type, PFA/Polyurethane Rubber Lining
For Flange Types of size 15 mm (0.5 in.) to 100 mm (4.0 in.), 300 mm (12 in.) to 400 mm (16 in.),
AXF Standard
shall be
selected.
Use
Converter
Output Signal
and
Communication
Power Supply
Lining (*7)
Electrode Material (*7)
General-Purpose Use
Submersible Type
Explosion proof Type (*4)
Integral Flowmeter with 4 to 20 mA DC Output and BRAIN Communication
Integral Flowmeter with 4 to 20 mA DC Output and HART Communication
Integral Flowmeter with Digital communication
(F
OUNDATION
Fieldbus protocol) (*8)
Integral Flowmeter with Digital communication
(PROFIBUS PA protocol) (*9)
Remote Flowtube for Combined Use with AXFA11
Remote Flowtube for Combined Use with AXFA14
Integral Flowmeter, 100 V to 240 V AC or 100 to 120 V DC
Integral Flowmeter, 24 V AC/DC
Remote Flowtube
JIS SUS316L (AISI 316L SS/EN 1.4404 Equivalent)
Platinum-iridium
Hastelloy C276 Equivalent
Tantalum
Titanium
Tungsten Carbide
Non-replaceable
Replaceable
None
JIS SUS316 (AISI 316 SS/EN 1.4401 Equivalent)
JIS SUS316L (AISI 316L SS/EN 1.4404 Equivalent)
Platinum-iridium
Hastelloy C276 Equivalent
Tantalum
Titanium
-D · · · · · · · · · · · · · · · · · ·
-E · · · · · · · · · · · · · · · · · ·
-F · · · · · · · · · · · · · · · · · ·
-G · · · · · · · · · · · · · · · · · ·
-N · · · · · · · · · · · · · · · · · ·
-P · · · · · · · · · · · · · · · · · ·
Fluorocarbon PFA
Polyurethane Rubber
Grounding Ring and
Grounding Electrode
Material (*7)
Size150 mm (6.0 in.), 200 mm (8.0 in.),
PFA lining only
Size150 mm (6.0 in.), 200 mm (8.0 in.),
PFA lining only
Process Connection
(*2)(*10)
ANSI Class 150
Flange (Carbon Steel)
ANSI Class 300
Flange (Carbon Steel)
DIN PN 10
Flange (Carbon Steel)(*1)
DIN PN 16
Flange (Carbon Steel)(*1)
JIS 10K
Flange (Carbon Steel)
JIS 20K
Flange (Carbon Steel)
JIS F12 (JIS75M)
Flange (Carbon Steel)
Size 150 mm (6.0 in.) to 250 mm (10 in.),
Not available for TIIS flameproof type
Size 150 mm (6.0 in.) to 250 mm (10 in.),
Not available for TIIS flameproof type
Size 200 mm (8.0 in.) to 250 mm (10 in.),
Not available for TIIS flameproof type
Size 150 mm (6.0 in.) to 250 mm (10 in.),
Not available for TIIS flameproof type
Size 150 mm (6.0 in.) to 250 mm (10 in.),
Not available for TIIS flameproof type
Size 150 mm (6.0 in.) to 250 mm (10 in.),
Not available for TIIS flameproof type
Size 150 mm (6.0 in.) to 250 mm (10 in.),
Not available for TIIS flameproof type
Lay Length
2 · · · · · · · Matches an Earlier ADMAG Flowmeter (ADMAG or ADMAG AE) for Replacement
Electrical Connection (*5)
Optional code (See the Table of Optional Specifications)
Standard
B · · ·
Calibration
Integral Flowmeter with indicator (Horizontal)
Integral Flowmeter with indicator(Vertical)
Integral Flowmeter without indicator /Remote Flowtube
Indicator (*3)(*6)
-0 · · · ·
-2 · · · ·
-4 · · · ·
JIS G1/2 female
ANSI 1/2 NPT female
ISO M20
1.5 female
1 · · ·
2 · · ·
N · · ·
/
Electrode Structure
-CA1 · · · · · · ·
-CA2 · · · · · · ·
-CD1 · · · · · · ·
-CD2 · · · · · · ·
-CJ1 · · · · · · ·
-CJ2 · · · · · · ·
-CG1 · · · · · · ·
N · · · · · · · · · · ·
S · · · · · · · · · · ·
L · · · · · · · · · · ·
P · · · · · · · · · · ·
H · · · · · · · · · · ·
T · · · · · · · · · · ·
V · · · · · · · · · · ·
1 · · · · · · · · · · · · ·
2 · · · · · · · · · · · · ·
L · · · · · · · · · · · · ·
P · · · · · · · · · · · · ·
H · · · · · · · · · · · · ·
T · · · · · · · · · · · · ·
V · · · · · · · · · · · · ·
W · · · · · · · · · · · · ·
1 · · · · · · · · · · · · · · · ·
2 · · · · · · · · · · · · · · · ·
N · · · · · · · · · · · · · · · ·
A · · · · · · · · · · · · · ·
U · · · · · · · · · · · · · ·
G · · · · · · · · · · · · · · · · · · · · ·
W · · · · · · · · · · · · · · · · · · · · ·
C · · · · · · · · · · · · · · · · · · · · ·
Model
Suffix Code
Description
Applicable Model
AXF150
AXF200
AXF250
· · · · · · · · · · · · · · · · · · · ·
· · · · · · · · · · · · · · · · · · · ·
· · · · · · · · · · · · · · · · · · · ·
Size 150 mm (6.0 in.) Integral Flowmeter/Remote Flowtube
Size 200 mm (8.0 in.) Integral Flowmeter/Remote Flowtube
Size 250 mm (10 in.) Integral Flowmeter/Remote Flowtube
T20.EPS
Remote Flowtube only
PFA lining only
PFA lining only
PFA lining only
General-Purpose use,Electrode Material :
JIS SUS316L only
Not available for Submersible Type
Not available for Submersible Type
Option