IM 01E20D01-01E
6-21
6. OUTLINE
AXF STANDARD (Clamp/Union/Butt Weld Connection)
Sanitary Type , PFA Lining
Use
Converter
Output Signal
and
Communication
Power Supply
Lining (*4)
Electrode Material (*4)
Sanitary Type
Integral Flowmeter with 4 to 20 mA DC Output and BRAIN Communication
Integral Flowmeter with 4 to 20 mA DC Output and HART Communication
Integral Flowmeter with Digital communication
(F
OUNDATION
Fieldbus protocol) (*5)
Integral Flowmeter with Digital communication
(PROFIBUS PA protocol) (*6)
Remote Flowtube for Combined use with AXFA11
Remote Flowtube for Combined use with AXFA14
Integral Flowmeter, 100 V to 240 V AC or 100 to 120 V DC
Integral Flowmeter, 24 V AC/DC
Remote Flowtube
JIS SUS316L (AISI 316L SS/EN 1.4404 Equivalent)
Non-replaceable
None
-D · · · · · · · · · · · · · · · · ·
-E · · · · · · · · · · · · · · · · ·
-F · · · · · · · · · · · · · · · · ·
-G · · · · · · · · · · · · · · · · ·
-N · · · · · · · · · · · · · · · · ·
-P · · · · · · · · · · · · · · · · ·
Fluorocarbon PFA
Grounding Ring
Process Connection
(*2) (*4) (*7)
Size 15 mm (0.5 in.) to 100 mm (4.0in.),
except 32 mm (1.25 in.)
Size 15 mm (0.5 in.) to 125 mm (5.0 in.)
Size 15 mm (0.5 in.) to 125 mm (5.0 in.)
Size 15 mm (0.5 in.) to 125 mm (5.0 in.)
Size 15 mm (0.5 in.) to 100 mm (4.0 in.)
Size 25 mm (1.0 in.) to 100 mm (4.0 in.)
Size 15 mm (0.5 in.) to 125 mm (5.0 in.)
Size 15 mm (0.5 in.) to 125 mm (5.0 in.)
Electrode Structure
-HAB · · · · · ·
-HDB · · · · · ·
-HKB · · · · · ·
-JDB
· · · · · ·
-JKB
· · · · · ·
-JSB
· · · · · ·
-KDB · · · · · ·
-KKB · · · · · ·
N · · · · · · · · · · · ·
1· · · · · · · · · · · · · ·
L
· · · · · · · · · · · · ·
1 · · · · · · · · · · · · · · · ·
2 · · · · · · · · · · · · · · · ·
N · · · · · · · · · · · · · · · ·
A
· · · · · · · · · · · · · ·
H · · · · · · · · · · · · · · · · · · · ·
Model
Suffix Code
Description
Applicable Model
AXF015
AXF025
AXF032
AXF040
AXF050
AXF065
AXF080
AXF100
AXF125
· · · · · · · · · · · · · · · · · · · ·
· · · · · · · · · · · · · · · · · · · ·
· · · · · · · · · · · · · · · · · · · ·
· · · · · · · · · · · · · · · · · · · ·
· · · · · · · · · · · · · · · · · · · ·
· · · · · · · · · · · · · · · · · · · ·
· · · · · · · · · · · · · · · · · · · ·
· · · · · · · · · · · · · · · · · · · ·
· · · · · · · · · · · · · · · · · · · ·
Size 15 mm (0.5 in.), Integral Flowmeter/Remote Flowtube
Size 25 mm (1.0 in.), Integral Flowmeter/Remote Flowtube
Size 32 mm (1.25 in.), Integral Flowmeter/Remote Flowtube
Size 40 mm (1.5 in.), Integral Flowmeter/Remote Flowtube
Size 50 mm (2.0 in.), Integral Flowmeter/Remote Flowtube
Size 65 mm (2.5 in.), Integral Flowmeter/Remote Flowtube
Size 80 mm (3.0 in.), Integral Flowmeter/Remote Flowtube
Size 100 mm (4.0 in.), Integral Flowmeter/Remote Flowtube
Size 125 mm (5.0 in.), Integral Flowmeter/Remote Flowtube
Lay Length
1 · · · · · · ·
Standard
High Grade (*8)
Electrical Connection
Optional code (See the Table of Optional Specifications)
Standard
B · · ·
C · · ·
Calibration
Integral Flowmeter with indicator (Horizontal)
Integral Flowmeter with indicator (Vertical)
Integral Flowmeter without indicator /Remote Flowtube
Indicator (*3)
-0 · · · ·
-2 · · · ·
-4 · · · ·
JIS G1/2 female
ANSI 1/2 NPT female
ISO M20
1.5 female
1 · · ·
2 · · ·
N · · ·
Size 25 mm (1.0 in.) to 125 mm (5.0 in.)
/
T18.EPS
*1: For a tri-clamp type of size15 mm (0.5 in.)(Process connection code: HAB), prepare a 3/4 in. tri-clamp on the process pipe side.
*2: The detail dimensions of process connections (clamp/union/butt weld) are shown in the ‘EXTERNAL DIMENSIONS’ section of the sanitary type.
In case of Butt Weld type, ferrules, sleeves, or alternative must be provided by the user. User need to weld these parts to the butt weld adapter.
*3: N shall be always selected for remote flowtubes.
In the case of an integral flowmeter, select from among the following figures.
*4:
Users must consider the characteristics of selected wetted parts material and influence of process fluids.
The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is
also possible that the instrument itself can be damaged and that fragments from the instrument can contaminate the user's process fluids.
Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite, and high-temperature
steam (150
°
C [302
°
F] or above). Contact Yokogawa for detailed information of the wetted parts material.
*5: For F
OUNDATION
Fieldbus protocol, refer to IM 01E20F02-01E
*6: For PROFIBUS PA protocol, refer to IM 01E20F12-01E.
*7: Allowable fluid pressure should also be limited according to fluid temperature and pressure.
*8: In the case of calibration code C in remote type, please order a combination of flowtube and converter.
1
2
N
Tri-Clamp (3A), JIS SUS316L or SUSF316L (AISI 316L SS/EN1.4404
Equivalent or ANSI F316L SS/EN1.4435 Equivalent)(*1)
DIN32676 Clamp, JIS SUS316L or SUSF316L (AISI 316L SS/EN1.4404
Equivalent or ANSI F316L SS/EN1.4435 Equivalent)
ISO2852/SMS3016 Clamp, JIS SUS316L or SUSF316L (AISI 316L SS/
EN1.4404 Equivalent or ANSI F316L SS/EN1.4435 Equivalent)
DIN11851 Union, SUS316L or SUSF316L (AISI 316L SS/EN1.4404
Equivalent or ANSI F316L SS/EN1.4435 Equivalent)
ISO2853 Union, SUS316L or SUSF316L (AISI 316L SS/EN1.4404
Equivalent or ANSI F316L SS/EN1.4435 Equivalent)
SMS1145 Union, SUS316L or SUSF316L (AISI 316L SS/EN1.4404
Equivalent or ANSI F316L SS/EN1.4435 Equivalent)
Butt Weld for DIN 11850 Pipe Connection
(SUS316L or SUSF316L [AISI 316L SS/EN1.4404 Equivalent or ANSI
F316L SS/EN1.4435 Equivalent])
Butt Weld for ISO 2037 Pipe Connection
(SUS316L or SUSF316L [AISI 316L SS/EN1.4404 Equivalent or ANSI
F316L SS/EN1.4435 Equivalent])
Option