![YOKOGAWA AXF series User Manual Download Page 89](http://html.mh-extra.com/html/yokogawa/axf-series/axf-series_user-manual_911230089.webp)
IM 01E20D01-01E
6-31
6. OUTLINE
■
EXTERNAL DIMENSIONS
AXF Standard, AXF002-AXF015, Wafer Type, PFA Lining
Unit : mm (approx. inch)
Remote Flowtube
Integral Flowmeter
Remote Flowtube
Integral Flowmeter
F22.EPS
*1: When indicator code N is selected, subtract 12 mm (0.47 inch)
from the value in the figure.
In case of explosion proof type with indicator, add 5 mm (0.2 inch) to it.
*2: Depending on the selection of grounding ring code and optional
code, add the following value to L (face-to-face length).
*3: When submersible type or option code DHC is selected,
waterproof glands and a 30m long cable are attached.
Add 9.5kg(20.9lb) to the weight in the table.
Option
Code
None
GA, GC, GD
(Special Gaskets)
Grounding Ring Code S, L, H, V
P, T
N
+0 +26(1.02)
-2(0.08)
+6(0.24) +28(1.10)
–
AXF002
AXF005
AXF010
AXF015
G
W
C
D
E
F
G
N
P
1
2
N
A
1
A
1
002
2.5(0.1)
A
005
5(0.2)
A
010
10(0.4)
A
015
15(0.5)
A
*
3
Max. Height
Hr
Hi
Weight kg (lb)
Max. Height
Weight kg (lb)
Height
H1
Size code
Size
Lining code
Face-to-face
length
L
*
2
Outside dia.
D
Inner diameter of
Grounding ring
ød
Model
Remote
flowtube
Integral
flowmeter
Remote
flowtube
Integral
flowmeter
81(3.19)
44(1.73)
15(0.59)
144(5.67)
268(10.55)
2.4(5.3)
306(12.03)
4.1(9.0)
*4
*4: D, E, F, G; Integral Flowmeter,
N, P; Remote Flowtube
* No infra-red switches are furnished
for Fieldbus communication type.
Hi
49(1.93)
73
(2.87)
Hr
H1
63.5(2.50)
3(0.12)
ø86(3.38)
48
L
*
2
Ground Terminal
(M4)
Ground Terminal
(M4)
ø128(5.04)
197(7.76)
*
1
154(6.06)
111(4.37)
28(1.1)
66
*
1
(2.6)
51.5
(2.03)
51.5
(2.03)
(1.89)
70(2.76)
72
58
D
(ød)
(2.83)
(2.28)
4- ø6.2(0.24)
AXF Standard, AXF025-AXF125, Wafer Type, PFA /Polyurethane Rubber /Natural Soft Rubber /EPDM
Rubber Lining
F23.EPS
*1: When indicator code N is selected, subtract 12
mm (0.47 inch) from the value in the figure.
In case of explosion proof type with indicator, add
5 mm (0.2 inch) to it.
*2: Depending on the selection of grounding ring
code and optional code, add the following value to
L (face-to-face length).
*3: When electrode structure 2 is selected, add the
following value to W (width).
*4: When submersible type or option code DHC is
selected, waterproof glands and a 30m long cable
are attached.
Add 9.5kg(20.9lb) to the weight in the table.
Nominal
Size
W
25
+52.5(2.07)
32, 40, 50
+52(2.05)
65, 80
+49(1.93)
100
+48(1.89)
125
+47(1.85)
Unit : mm (approx. inch)
49(1.93)
L
*
2
øD
(ød)
W
*
3
Ground Terminal
(M4)
111(4.37)
28(1.1)
66
*
1
(2.6)
51.5
(2.03)
51.5
(2.03)
ø128(5.04)
70
(2.76)
73(2.87)
Ground Terminal
(M4)
Remote Flowtube
Integral flowmeter
Remote Flowtube
Integral flowmeter
Hi
Hr
Hr
154(6.06)
ø86(3.38)
48(1.89)
197(7.76)
*
1
*5
*5: D, E, F, G; Integral Flowmeter,
N, P; Remote Flowtube
Option
Code
None
GA, GC, GD
(Special Gaskets)
Grounding Ring Code
S, L, H, V
P, T
N
+0 +26(1.02)
-2(0.08)
+8(0.31) +30(1.18)
–
AXF025
AXF032
AXF040
AXF050
AXF065
AXF080
AXF100
AXF125
G
W
C
D
E
F
G
N
P
A
U
D
G
1
2
N
1
2
A
1
* No infra-red switches are furnished
for Fieldbus communication type.
025
25(1)
A,U
60(2.36)
67.5(2.66)
28(1.10)
67.5(2.66)
92(3.62)
216(8.50)
1.9(4.1)
254(9.98)
3.6(7.8)
032
32(1.25)
A,U
70(2.76)
73(2.87)
34(1.34)
73(2.87)
98(3.86)
222(8.74)
2.0(4.5)
260(10.24)
3.7(8.2)
065
65(2.5)
A,U
D,G
100(3.94)
117(4.61)
66(2.60)
117(4.61)
147(5.79)
271(10.67)
3.4(7.6)
309(12.17)
5.1(11.3)
040
40(1.5)
A,U
70(2.76)
86(3.39)
41(1.61)
86(3.39)
111(4.37)
235(9.25)
2.2(4.9)
273(10.73)
3.9(8.7)
050
50(2)
A,U
D,G
80(3.15)
99(3.90)
53(2.09)
99(3.90)
129(5.08)
253(9.96)
2.7(5.8)
291(11.44)
4.4(9.6)
080
80(3)
A,U
D,G
120(4.72)
129(5.08)
77(3.03)
129(5.08)
157(6.18)
281(11.06)
4.1(9.1)
319(12.54)
5.8(12.9)
100
100(4)
A,U
D,G
150(5.91)
155(6.10)
102(4.02)
155(6.10)
183(7.20)
307(12.09)
5.6(12.3)
345(13.56)
7.3(16.0)
125
125(5)
A,U
D,G
200(7.87)
183(7.20)
128(5.04)
183(7.20)
212(8.35)
336(13.23)
9.3(20.4)
374(14.70)
11.0(24.2)
*
3
W
*
4
Max. Height Hr
Hi
Weight kg (lb)
Max. Height
Weight kg (lb)
Height
H1
Size code
Size
Lining code
Face-to-face
length
L
*
2
Outside dia.
ø
D
Inner diameter of
Grounding ring
ø
d
Width
Model
Remote
Flowtube
Integral
Flowmeter
Remote
Flowtube
Integral
Flowmeter