IM 01E20D01-01E
3-22
3. INSTALLATION
CAUTION
• In case of standard gasket (EPDM rubber),
tighten the adapter mounting screw according
to the torque values in Table 3.3.18.
• In case that optional code GH (Silicon rubber)
is selected, tighten the adapter mounting screw
according to the torque values in Table 3.3.19.
• Tighten the adapter mounting screw in diagonal
order step by step.
• After tightening of screw, confirm that gaskets
protrude inside adapter. Protruding of gasket is
necessary to keep the sanitary requirements.
Table 3.3.18
Tightening Torque Values of adapter for
EPDM rubber gasket
T0502.EPS
Size mm (inch)
Gasket type
Tightening torque values (N-m / {kgf-cm} / [in-lbf])
15 (0.5), 25 (1.0), 32 (1.25), 40 (1.5)
50 (2.0), 65 (2.5)
80 (3.0)
100 (4.0), 125 (5.0)
3.0 to 3.5 / {30.59 to 35.69} / [26.55 to 30.98]
4.5 to 5.0 / {45.89 to 50.99} / [39.83 to 44.25]
8.0 to 9.0 / {81.58 to 91.78} / [70.81 to 79.65]
10 to 11 / {102.0 to 112.2} / [88.50 to 97.35]
EPDM rubber
(standard)
Table 3.3.19
Tightening Torque Values of adapter for
silicon rubber gasket
T0503.EPS
Size mm (inch)
Gasket type
Tightening torque values (N-m / {kgf-cm} / [in-lbf])
15 (0.5), 25 (1.0), 32 (1.25), 40 (1.5)
50 (2.0), 65 (2.5), 80 (3.0)
100 (4.0), 125 (5.0)
2.0 to 2.5 / {20.39 to 25.49} / [17.70 to 22.13]
4.0 to 4.5 / {40.79 to 45.89} / [35.40 to 39.83]
6.0 to 6.5 / {61.18 to 66.28} / [53.10 to 57.53]
Silicon rubber
(optional code GH)
4) Mounting flowmeter to piping
Connect the flowmeter to the piping in a manner
appropriate to the ferrule, the sleeve, or the
alternative that has been welded to the adapter.
5) Confirmation of adapter mounting screw
After installation of the magnetic flowmeter, be
sure to retighten the adapter mounting screw
according to Table 3.3.18 or Table 3.3.19.
Be sure to confirm that leakage from adapter
connection point does not occur by filling the
pipe of the flowtube with fluid.
Gasket
Mini-flange
Butt weld adapter
Adapter
mounting screw
F0316.EPS
Figure 3.3.8
Mounting Procedure for Weld Joint Adapter
Type
(3) Maintenance of Sanitary Type
Refer to Section 5.3.